Page 1 Fri Mar 23 14:48:39 2018
|
||||
|
||||
******************************************************************
|
||||
* E P A N E T *
|
||||
* Hydraulic and Water Quality *
|
||||
* Analysis for Pipe Networks *
|
||||
* Version 2.00.12 *
|
||||
******************************************************************
|
||||
|
||||
Analysis begun Fri Mar 23 14:48:39 2018
|
||||
|
||||
|
||||
Hydraulic Status:
|
||||
-----------------------------------------------------------------------
|
||||
0:00:00: Balancing the network:
|
||||
Trial 1: relative flow change = 6.551358
|
||||
Trial 2: relative flow change = 1.197136
|
||||
Trial 3: relative flow change = 1.229316
|
||||
Trial 4: relative flow change = 1.319952
|
||||
Trial 5: relative flow change = 1.668231
|
||||
Trial 6: relative flow change = 1.147804
|
||||
Trial 7: relative flow change = 0.303981
|
||||
Trial 8: relative flow change = 0.013634
|
||||
Trial 9: relative flow change = 0.000030
|
||||
0:00:00: Balanced after 9 trials
|
||||
0:00:00: Reservoir B is emptying
|
||||
0:00:00: Reservoir A is emptying
|
||||
|
||||
Analysis ended Fri Mar 23 14:48:39 2018
|
||||