Page 1 Fri Mar 23 14:48:40 2018
|
||||
|
||||
******************************************************************
|
||||
* E P A N E T *
|
||||
* Hydraulic and Water Quality *
|
||||
* Analysis for Pipe Networks *
|
||||
* Version 2.00.12 *
|
||||
******************************************************************
|
||||
|
||||
Analysis begun Fri Mar 23 14:48:40 2018
|
||||
|
||||
|
||||
Hydraulic Status:
|
||||
-----------------------------------------------------------------------
|
||||
0:00:00: Balancing the network:
|
||||
Trial 1: relative flow change = 0.892654
|
||||
Trial 2: relative flow change = 1.072474
|
||||
PRV 5 switched from active to closed
|
||||
FCV 4 switched from active to open
|
||||
Trial 3: relative flow change = 77.341455
|
||||
Trial 4: relative flow change = 0.000004
|
||||
0:00:00: Balanced after 4 trials
|
||||
0:00:00: Reservoir 1 is closed
|
||||
0:00:00: Reservoir 6 is closed
|
||||
0:00:00: FCV 4 open but cannot deliver flow
|
||||
0:00:00: PRV 5 closed
|
||||
|
||||
WARNING: FCV 4 open but cannot deliver flow at 0:00:00 hrs.
|
||||
|
||||
Analysis ended Fri Mar 23 14:48:40 2018
|
||||