Fix for FCV problem
This update prevents a solution where the computed loss coefficient for a FCV at its flow setting would be less than the user supplied fully opened coefficient.
This commit is contained in:
@@ -7,7 +7,7 @@ Description: updates hydraulic status of network elements
|
||||
Authors: see AUTHORS
|
||||
Copyright: see AUTHORS
|
||||
License: see LICENSE
|
||||
Last Updated: 05/15/2019
|
||||
Last Updated: 08/08/2022
|
||||
******************************************************************************
|
||||
*/
|
||||
|
||||
@@ -394,6 +394,15 @@ StatusType fcvstatus(Project *pr, int k, StatusType s, double h1, double h2)
|
||||
{
|
||||
status = ACTIVE;
|
||||
}
|
||||
|
||||
// Active valve's loss coeff. can't be < fully open loss coeff.
|
||||
else if (status == ACTIVE)
|
||||
{
|
||||
if ((h1 - h2) / SQR(hyd->LinkFlow[k] < pr->network.Link[k].Km)
|
||||
{
|
||||
status = XFCV;
|
||||
}
|
||||
}
|
||||
return status;
|
||||
}
|
||||
|
||||
|
||||