@@ -1,13 +1,13 @@
|
||||
/*
|
||||
******************************************************************************
|
||||
Project: OWA EPANET
|
||||
Version: 2.2
|
||||
Version: 2.3
|
||||
Module: hydraul.c
|
||||
Description: implements EPANET's hydraulic engine
|
||||
Authors: see AUTHORS
|
||||
Copyright: see AUTHORS
|
||||
License: see LICENSE
|
||||
Last Updated: 06/26/2024
|
||||
Last Updated: 04/19/2025
|
||||
******************************************************************************
|
||||
*/
|
||||
|
||||
@@ -71,7 +71,7 @@ int openhyd(Project *pr)
|
||||
if (!errcode) for (i = 1; i <= pr->network.Nlinks; i++)
|
||||
{
|
||||
link = &pr->network.Link[i];
|
||||
initlinkflow(pr, i, link->Status, link->Kc);
|
||||
initlinkflow(pr, i, link->InitStatus, link->Kc);
|
||||
}
|
||||
else closehyd(pr);
|
||||
return errcode;
|
||||
@@ -124,9 +124,12 @@ void inithyd(Project *pr, int initflag)
|
||||
link->ResultIndex = i;
|
||||
|
||||
// Initialize status and setting
|
||||
hyd->LinkStatus[i] = link->Status;
|
||||
hyd->LinkSetting[i] = link->Kc;
|
||||
|
||||
hyd->LinkStatus[i] = link->InitStatus;
|
||||
hyd->LinkSetting[i] = link->InitSetting;
|
||||
|
||||
// Set runtime setting of non-ACTIVE valves to "MISSING"
|
||||
if (link->Type >= PRV && link->InitStatus != ACTIVE) link->Kc = MISSING;
|
||||
|
||||
// Compute flow resistance
|
||||
resistcoeff(pr, i);
|
||||
|
||||
|
||||