From 57ae3eeab8ed9d3834688776f72d3f5f46c05904 Mon Sep 17 00:00:00 2001 From: Sam Hatchett Date: Thu, 19 Jan 2023 14:16:50 -0500 Subject: [PATCH] Update ReleaseNotes2_3.md --- ReleaseNotes2_3.md | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/ReleaseNotes2_3.md b/ReleaseNotes2_3.md index 5a3b2d3..2a51cd6 100644 --- a/ReleaseNotes2_3.md +++ b/ReleaseNotes2_3.md @@ -25,6 +25,7 @@ This document describes the changes and updates that have been made in version 2 - A possible loss of network connectivity when evaluating a Pressure Sustaining Valve was prevented. - Having the implied loss coefficient for an active Flow Control Valve be less than its fully opened value was prevented. - A new type of valve, a Positional Control Valve (PCV), was added that uses a valve characteristic curve to relate its loss coefficient to its fraction open setting. - + - A new set of functions have been added to get information about upcoming time step events. Users will now see what type of event is going to cause the end of a time step to occur. See ENtimetonextevent and EN_timetonextevent. + - A new set of functions have been added to allow users to set a reporting callback function. The user-supplied function will recieve all output normally directed to the report file.