Added additional network building features (#367)
This commit is contained in:
@@ -5,7 +5,7 @@ Attribute VB_Name = "Module1"
|
||||
'Declarations of functions in the EPANET PROGRAMMERs TOOLKIT
|
||||
'(EPANET2.DLL)
|
||||
|
||||
'Last updated on 4/3/07
|
||||
'Last updated on 01/01/2019
|
||||
|
||||
' These are codes used by the DLL functions
|
||||
Public Const EN_ELEVATION = 0 ' Node parameters
|
||||
@@ -50,15 +50,16 @@ Public Const EN_HEADLOSS = 10
|
||||
Public Const EN_STATUS = 11
|
||||
Public Const EN_SETTING = 12
|
||||
Public Const EN_ENERGY = 13
|
||||
Public Const EN_LINKQUAL = 14 'ES
|
||||
Public Const EN_LINKQUAL = 14
|
||||
Public Const EN_LINKPATTERN = 15
|
||||
Public Const EN_EFFICIENCY = 16
|
||||
Public Const EN_HEADCURVE = 17
|
||||
Public Const EN_EFFICIENCYCURVE = 18
|
||||
Public Const EN_PRICEPATTERN = 19
|
||||
Public Const EN_STATE = 20
|
||||
Public Const EN_CONST_POWER = 21
|
||||
Public Const EN_SPEED = 22
|
||||
|
||||
Public Const EN_PUMP_STATE = 16
|
||||
Public Const EN_PUMP_EFFIC = 17
|
||||
Public Const EN_PUMP_POWER = 18
|
||||
Public Const EN_PUMP_HCURVE = 19
|
||||
Public Const EN_PUMP_ECURVE = 20
|
||||
Public Const EN_PUMP_ECOST = 21
|
||||
Public Const EN_PUMP_EPAT = 22
|
||||
|
||||
Public Const EN_DURATION = 0 ' Time parameters
|
||||
Public Const EN_HYDSTEP = 1
|
||||
@@ -76,13 +77,13 @@ Public Const EN_QTIME = 12
|
||||
Public Const EN_HALTFLAG = 13
|
||||
Public Const EN_NEXTEVENT = 14
|
||||
|
||||
Public Const EN_ITERATIONS = 0
|
||||
Public Const EN_ITERATIONS = 0 ' Run statistics
|
||||
Public Const EN_RELATIVEERROR = 1
|
||||
Public Const EN_MAXHEADERROR = 2
|
||||
Public Const EN_MAXFLOWCHANGE = 3
|
||||
Public Const EN_MASSBALANCE = 4
|
||||
|
||||
Public Const EN_NODECOUNT = 0 'Component counts
|
||||
Public Const EN_NODECOUNT = 0 ' Component counts
|
||||
Public Const EN_TANKCOUNT = 1
|
||||
Public Const EN_LINKCOUNT = 2
|
||||
Public Const EN_PATCOUNT = 3
|
||||
@@ -114,7 +115,7 @@ Public Const EN_MASS = 1
|
||||
Public Const EN_SETPOINT = 2
|
||||
Public Const EN_FLOWPACED = 3
|
||||
|
||||
Public Const EN_HW = 0 ' Head loss formula
|
||||
Public Const EN_HW = 0 ' Head loss formulas
|
||||
Public Const EN_DW = 1
|
||||
Public Const EN_CM = 2
|
||||
|
||||
@@ -132,7 +133,7 @@ Public Const EN_CMD = 9
|
||||
Public Const EN_DDA = 0 ' Demand driven analysis
|
||||
Public Const EN_PDA = 1 ' Pressure driven analysis
|
||||
|
||||
Public Const EN_TRIALS = 0 ' Misc. options
|
||||
Public Const EN_TRIALS = 0 ' Hydraulic options
|
||||
Public Const EN_ACCURACY = 1
|
||||
Public Const EN_TOLERANCE = 2
|
||||
Public Const EN_EMITEXPON = 3
|
||||
@@ -141,41 +142,82 @@ Public Const EN_HEADERROR = 5
|
||||
Public Const EN_FLOWCHANGE = 6
|
||||
Public Const EN_DEMANDDEFPAT = 7
|
||||
Public Const EN_HEADLOSSFORM = 8
|
||||
Public Const EN_GLOBALEFFIC = 9
|
||||
Public Const EN_GLOBALPRICE = 10
|
||||
Public Const EN_GLOBALPATTERN = 11
|
||||
Public Const EN_DEMANDCHARGE = 12
|
||||
|
||||
Public Const EN_LOWLEVEL = 0 ' Control types
|
||||
Public Const EN_LOWLEVEL = 0 ' Control types
|
||||
Public Const EN_HILEVEL = 1
|
||||
Public Const EN_TIMER = 2
|
||||
Public Const EN_TIMEOFDAY = 3
|
||||
|
||||
Public Const EN_AVERAGE = 1 'Time statistic types
|
||||
Public Const EN_AVERAGE = 1 ' Time statistic types
|
||||
Public Const EN_MINIMUM = 2
|
||||
Public Const EN_MAXIMUM = 3
|
||||
Public Const EN_RANGE = 4
|
||||
|
||||
Public Const EN_MIX1 = 0 'Tank mixing models
|
||||
Public Const EN_MIX1 = 0 ' Tank mixing models
|
||||
Public Const EN_MIX2 = 1
|
||||
Public Const EN_FIFO = 2
|
||||
Public Const EN_LIFO = 3
|
||||
|
||||
Public Const EN_NOSAVE = 0 ' Save-results-to-file flag
|
||||
Public Const EN_NOSAVE = 0 ' Save-results-to-file flag
|
||||
Public Const EN_SAVE = 1
|
||||
Public Const EN_INITFLOW = 10 ' Re-initialize flow flag
|
||||
Public Const EN_SAVE_AND_INIT = 11
|
||||
|
||||
Public Const EN_INITFLOW = 10 ' Re-initialize flow flag
|
||||
Public Const EN_CONST_HP = 0 ' Constant horsepower pump curve
|
||||
Public Const EN_POWER_FUNC = 1 ' Power function pump cuve
|
||||
Public Const EN_CUSTOM = 2 ' User-defined custom pump curve
|
||||
Public Const EN_NOCURVE = 3 ' No pump curve
|
||||
|
||||
Public Const EN_CONST_HP = 0 ' constant horsepower
|
||||
Public Const EN_POWER_FUNC = 1 ' power function
|
||||
Public Const EN_CUSTOM = 2 ' user-defined custom curve
|
||||
Public Const EN_NOCURVE = 3 ' no curve
|
||||
|
||||
Public Const EN_V_CURVE = 0 ' volume curve
|
||||
Public Const EN_P_CURVE = 1 ' pump curve
|
||||
Public Const EN_E_CURVE = 2 ' efficiency curve
|
||||
Public Const EN_H_CURVE = 3 ' head loss curve
|
||||
Public Const EN_G_CURVE = 4 ' General\default curve
|
||||
Public Const EN_VOLUME_CURVE = 0 ' Volume curve
|
||||
Public Const EN_PUMP_CURVE = 1 ' Pump curve
|
||||
Public Const EN_EFFIC_CURVE = 2 ' Efficiency curve
|
||||
Public Const EN_HLOSS_CURVE = 3 ' Head loss curve
|
||||
Public Const EN_GENERIC_CURVE = 4 ' Generic curve
|
||||
|
||||
Public Const EN_UNCONDITIONAL = 0 ' Unconditional object deletion
|
||||
Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
|
||||
Public Const EN_NO_REPORT = 0 ' No status report
|
||||
Public Const EN_NORMAL_REPORT = 1 ' Normal status report
|
||||
Public Const EN_FULL_REPORT = 2 ' Full status report
|
||||
|
||||
Public Const EN_R_NODE = 6 ' Rule objects
|
||||
Public Const EN_R_LINK = 7
|
||||
Public Const EN_R_SYSTEM = 8
|
||||
|
||||
Public Const EN_R_DEMAND = 0 ' Rule variables
|
||||
Public Const EN_R_HEAD = 1
|
||||
Public Const EN_R_GRADE = 2
|
||||
Public Const EN_R_LEVEL = 3
|
||||
Public Const EN_R_PRESSURE = 4
|
||||
Public Const EN_R_FLOW = 5
|
||||
Public Const EN_R_STATUS = 6
|
||||
Public Const EN_R_SETTING = 7
|
||||
Public Const EN_R_POWER = 8
|
||||
Public Const EN_R_TIME = 9
|
||||
Public Const EN_R_CLOCKTIME = 10
|
||||
Public Const EN_R_FILLTIME = 11
|
||||
Public Const EN_R_DRAINTIME = 12
|
||||
|
||||
Public Const EN_R_EQ = 0 ' Rule operators
|
||||
Public Const EN_R_NE = 1
|
||||
Public Const EN_R_LE = 2
|
||||
Public Const EN_R_GE = 3
|
||||
Public Const EN_R_LT = 4
|
||||
Public Const EN_R_GT = 5
|
||||
Public Const EN_R_IS = 6
|
||||
Public Const EN_R_NOT = 7
|
||||
Public Const EN_R_BELOW = 8
|
||||
Public Const EN_R_ABOVE = 9
|
||||
|
||||
Public Const EN_R_IS_OPEN = 1 ' Rule status types
|
||||
Public Const EN_R_IS_CLOSED = 2
|
||||
Public Const EN_R_IS_ACTIVE = 3
|
||||
|
||||
'These are the external functions that comprise the DLL
|
||||
|
||||
'System Functions
|
||||
@@ -236,6 +278,8 @@ Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
Declare Function ENgetnodetype Lib "epanet2.dll" (ByVal index As Long, code As Long) As Long
|
||||
Declare Function ENgetnodevalue Lib "epanet2.dll" (ByVal index As Long, ByVal code As Long, value As Single) As Long
|
||||
Declare Function ENsetnodevalue Lib "epanet2.dll" (ByVal index As Long, ByVal code As Long, ByVal value As Single) As Long
|
||||
Declare Function ENsetjuncdata Lib "epanet2.dll" (ByVal index As Long, ByVal elev As Single, ByVal dmnd As Single, ByVal dmndpat As String) As Long
|
||||
Declare Function ENsettankdata Lib "epanet2.dll" (ByVal index As Long, ByVal elev As Single, ByVal initlvl As Single, ByVal minlvl As Single, ByVal maxlvl As Single, ByVal diam As Single, ByVal minvol As Single, ByVal volcurve As String) As Long
|
||||
Declare Function ENgetcoord Lib "epanet2.dll" (ByVal index As Long, X As Single, Y As Single) As Long
|
||||
Declare Function ENsetcoord Lib "epanet2.dll" (ByVal index As Long, ByVal X As Single, ByVal Y As Single) As Long
|
||||
|
||||
@@ -262,6 +306,7 @@ Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
Declare Function ENsetlinknodes Lib "epanet2.dll" (ByVal index As Long, ByVal node1 As Long, ByVal node2 As Long) As Long
|
||||
Declare Function ENgetlinkvalue Lib "epanet2.dll" (ByVal index As Long, ByVal code As Long, value As Single) As Long
|
||||
Declare Function ENsetlinkvalue Lib "epanet2.dll" (ByVal index As Long, ByVal code As Long, ByVal value As Single) As Long
|
||||
Declare Function ENsetpipedata Lib "epanet2.dll" (ByVal index As Long, ByVal length As Single, ByVal diam As Single, ByVal rough As Single, ByVal mloss As Single) As Long
|
||||
|
||||
'Pump Functions
|
||||
Declare Function ENgetheadcurveindex Lib "epanet2.dll" (ByVal pumpIndex As Long, curveIndex As Long) As Long
|
||||
|
||||
@@ -7,7 +7,7 @@
|
||||
Authors: see AUTHORS
|
||||
Copyright: see AUTHORS
|
||||
License: see LICENSE
|
||||
Last Updated: 11/29/2018
|
||||
Last Updated: 12/31/2018
|
||||
******************************************************************************
|
||||
*/
|
||||
|
||||
@@ -44,12 +44,6 @@
|
||||
#endif // __cplusplus
|
||||
#elif defined(CYGWIN)
|
||||
#define DLLEXPORT __stdcall
|
||||
#elif defined(__APPLE__)
|
||||
#ifdef __cplusplus
|
||||
#define DLLEXPORT
|
||||
#else
|
||||
#define DLLEXPORT
|
||||
#endif
|
||||
#else
|
||||
#define DLLEXPORT
|
||||
#endif
|
||||
@@ -510,6 +504,34 @@ extern "C" {
|
||||
*/
|
||||
int DLLEXPORT ENsetnodevalue(int index, int code, EN_API_FLOAT_TYPE v);
|
||||
|
||||
/**
|
||||
@brief Set a group of properties for a junction node.
|
||||
@param index The index of a junction node.
|
||||
@param elev The junction's elevation.
|
||||
@param dmnd The junction's primary base demand.
|
||||
@param dmndpat The name of the demand's time pattern ("" for no pattern)
|
||||
@return Error code.
|
||||
*/
|
||||
int DLLEXPORT ENsetjuncdata(int index, EN_API_FLOAT_TYPE elev,
|
||||
EN_API_FLOAT_TYPE dmnd, char *dmndpat);
|
||||
|
||||
/**
|
||||
@brief Set a group of properties for a tank node.
|
||||
@param index The index of a tank node.
|
||||
@param elev The tank's bottom elevation.
|
||||
@param initlvl The initial water level in the tank.
|
||||
@param minlvl The minimum water level for the tank.
|
||||
@param maxlvl The maximum water level for the tank.
|
||||
@param diam The tank's diameter (0 if volume curve used).
|
||||
@param minvol The volume of the tank at its minimum water level.
|
||||
@param volcurve The name of the tank's volume curve ("" for no curve)
|
||||
@return Error code.
|
||||
*/
|
||||
int DLLEXPORT ENsettankdata(int index, EN_API_FLOAT_TYPE elev,
|
||||
EN_API_FLOAT_TYPE initlvl, EN_API_FLOAT_TYPE minlvl,
|
||||
EN_API_FLOAT_TYPE maxlvl, EN_API_FLOAT_TYPE diam,
|
||||
EN_API_FLOAT_TYPE minvol, char *volcurve);
|
||||
|
||||
/**
|
||||
@brief Get coordinates (x,y) for a node.
|
||||
@param index The index of a node (first node is index 1).
|
||||
@@ -743,6 +765,20 @@ extern "C" {
|
||||
*/
|
||||
int DLLEXPORT ENsetlinkvalue(int index, int code, EN_API_FLOAT_TYPE v);
|
||||
|
||||
/**
|
||||
@brief Set a collection of property values for a pipe link.
|
||||
@param index The index of a pipe link.
|
||||
@param length The pipe's length.
|
||||
@param diam The pipe's diameter.
|
||||
@param rough The pipe's roughness coefficient.
|
||||
@param mloss The pipe's minor loss coefficient.
|
||||
@return Error code.
|
||||
*/
|
||||
int DLLEXPORT ENsetpipedata(int index, EN_API_FLOAT_TYPE length,
|
||||
EN_API_FLOAT_TYPE diam, EN_API_FLOAT_TYPE rough,
|
||||
EN_API_FLOAT_TYPE mloss);
|
||||
|
||||
|
||||
/********************************************************************
|
||||
|
||||
Pump Functions
|
||||
|
||||
@@ -4,7 +4,7 @@
|
||||
'Declarations of functions in the EPANET PROGRAMMERs TOOLKIT
|
||||
'(EPANET2.DLL) for use with VB.Net.
|
||||
|
||||
'Last updated on 7/19/15 - LR
|
||||
'Last updated on 01/01/2019
|
||||
|
||||
Imports System.Runtime.InteropServices
|
||||
Imports System.Text
|
||||
@@ -55,15 +55,16 @@ Public Const EN_HEADLOSS = 10
|
||||
Public Const EN_STATUS = 11
|
||||
Public Const EN_SETTING = 12
|
||||
Public Const EN_ENERGY = 13
|
||||
Public Const EN_LINKQUAL = 14 'ES
|
||||
Public Const EN_LINKQUAL = 14
|
||||
Public Const EN_LINKPATTERN = 15
|
||||
Public Const EN_EFFICIENCY = 16
|
||||
Public Const EN_HEADCURVE = 17
|
||||
Public Const EN_EFFICIENCYCURVE = 18
|
||||
Public Const EN_PRICEPATTERN = 19
|
||||
Public Const EN_STATE = 20
|
||||
Public Const EN_CONST_POWER = 21
|
||||
Public Const EN_SPEED = 22
|
||||
|
||||
Public Const EN_PUMP_STATE = 16
|
||||
Public Const EN_PUMP_EFFIC = 17
|
||||
Public Const EN_PUMP_POWER = 18
|
||||
Public Const EN_PUMP_HCURVE = 19
|
||||
Public Const EN_PUMP_ECURVE = 20
|
||||
Public Const EN_PUMP_ECOST = 21
|
||||
Public Const EN_PUMP_EPAT = 22
|
||||
|
||||
Public Const EN_DURATION = 0 ' Time parameters
|
||||
Public Const EN_HYDSTEP = 1
|
||||
@@ -75,7 +76,7 @@ Public Const EN_REPORTSTART = 6
|
||||
Public Const EN_RULESTEP = 7
|
||||
Public Const EN_STATISTIC = 8
|
||||
Public Const EN_PERIODS = 9
|
||||
Public Const EN_STARTTIME = 10 'ES
|
||||
Public Const EN_STARTTIME = 10
|
||||
Public Const EN_HTIME = 11
|
||||
Public Const EN_QTIME = 12
|
||||
Public Const EN_HALTFLAG = 13
|
||||
@@ -119,7 +120,7 @@ Public Const EN_MASS = 1
|
||||
Public Const EN_SETPOINT = 2
|
||||
Public Const EN_FLOWPACED = 3
|
||||
|
||||
Public Const EN_HW = 0 ' Head loss formula
|
||||
Public Const EN_HW = 0 ' Head loss formulas
|
||||
Public Const EN_DW = 1
|
||||
Public Const EN_CM = 2
|
||||
|
||||
@@ -137,7 +138,7 @@ Public Const EN_CMD = 9
|
||||
Public Const EN_DDA = 0 ' Demand driven analysis
|
||||
Public Const EN_PDA = 1 ' Pressure driven analysis
|
||||
|
||||
Public Const EN_TRIALS = 0 ' Misc. options
|
||||
Public Const EN_TRIALS = 0 ' Hydraulic options
|
||||
Public Const EN_ACCURACY = 1
|
||||
Public Const EN_TOLERANCE = 2
|
||||
Public Const EN_EMITEXPON = 3
|
||||
@@ -146,39 +147,82 @@ Public Const EN_HEADERROR = 5
|
||||
Public Const EN_FLOWCHANGE = 6
|
||||
Public Const EN_DEMANDDEFPAT = 7
|
||||
Public Const EN_HEADLOSSFORM = 8
|
||||
Public Const EN_GLOBALEFFIC = 9
|
||||
Public Const EN_GLOBALPRICE = 10
|
||||
Public Const EN_GLOBALPATTERN = 11
|
||||
Public Const EN_DEMANDCHARGE = 12
|
||||
|
||||
Public Const EN_LOWLEVEL = 0 ' Control types
|
||||
Public Const EN_LOWLEVEL = 0 ' Control types
|
||||
Public Const EN_HILEVEL = 1
|
||||
Public Const EN_TIMER = 2
|
||||
Public Const EN_TIMEOFDAY = 3
|
||||
|
||||
Public Const EN_AVERAGE = 1 'Time statistic types
|
||||
Public Const EN_AVERAGE = 1 ' Time statistic types
|
||||
Public Const EN_MINIMUM = 2
|
||||
Public Const EN_MAXIMUM = 3
|
||||
Public Const EN_RANGE = 4
|
||||
|
||||
Public Const EN_MIX1 = 0 'Tank mixing models
|
||||
Public Const EN_MIX1 = 0 ' Tank mixing models
|
||||
Public Const EN_MIX2 = 1
|
||||
Public Const EN_FIFO = 2
|
||||
Public Const EN_LIFO = 3
|
||||
|
||||
Public Const EN_NOSAVE = 0 ' Save-results-to-file flag
|
||||
Public Const EN_NOSAVE = 0 ' Save-results-to-file flag
|
||||
Public Const EN_SAVE = 1
|
||||
Public Const EN_INITFLOW = 10 ' Re-initialize flow flag
|
||||
Public Const EN_INITFLOW = 10 ' Re-initialize flow flag
|
||||
Public Const EN_SAVE_AND_INIT = 11
|
||||
|
||||
Public Const EN_CONST_HP = 0 ' constant horsepower
|
||||
Public Const EN_POWER_FUNC = 1 ' power function
|
||||
Public Const EN_CUSTOM = 2 ' user-defined custom curve
|
||||
Public Const EN_CONST_HP = 0 ' Constant horsepower pump curve
|
||||
Public Const EN_POWER_FUNC = 1 ' Power function pump curve
|
||||
Public Const EN_CUSTOM = 2 ' User-defined custom pump curve
|
||||
Public Const EN_NOCURVE = 3 ' No pump curve
|
||||
|
||||
Public Const EN_V_CURVE = 0 ' volume curve
|
||||
Public Const EN_P_CURVE = 1 ' pump curve
|
||||
Public Const EN_E_CURVE = 2 ' efficiency curve
|
||||
Public Const EN_H_CURVE = 3 ' head loss curve
|
||||
Public Const EN_G_CURVE = 4 ' General\default curve
|
||||
Public Const EN_VOLUME_CURVE = 0 ' Volume curve
|
||||
Public Const EN_PUMP_CURVE = 1 ' Pump curve
|
||||
Public Const EN_EFFIC_CURVE = 2 ' Efficiency curve
|
||||
Public Const EN_HLOSS_CURVE = 3 ' Head loss curve
|
||||
Public Const EN_GENERIC_CURVE = 4 ' Generic curve
|
||||
|
||||
Public Const EN_UNCONDITIONAL = 0 ' Unconditional object deletion
|
||||
Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
|
||||
Public Const EN_NO_REPORT = 0 ' No status report
|
||||
Public Const EN_NORMAL_REPORT = 1 ' Normal status report
|
||||
Public Const EN_FULL_REPORT = 2 ' Full status report
|
||||
|
||||
Public Const EN_R_NODE = 6 ' Rule objects
|
||||
Public Const EN_R_LINK = 7
|
||||
Public Const EN_R_SYSTEM = 8
|
||||
|
||||
Public Const EN_R_DEMAND = 0 ' Rule variables
|
||||
Public Const EN_R_HEAD = 1
|
||||
Public Const EN_R_GRADE = 2
|
||||
Public Const EN_R_LEVEL = 3
|
||||
Public Const EN_R_PRESSURE = 4
|
||||
Public Const EN_R_FLOW = 5
|
||||
Public Const EN_R_STATUS = 6
|
||||
Public Const EN_R_SETTING = 7
|
||||
Public Const EN_R_POWER = 8
|
||||
Public Const EN_R_TIME = 9
|
||||
Public Const EN_R_CLOCKTIME = 10
|
||||
Public Const EN_R_FILLTIME = 11
|
||||
Public Const EN_R_DRAINTIME = 12
|
||||
|
||||
Public Const EN_R_EQ = 0 ' Rule operators
|
||||
Public Const EN_R_NE = 1
|
||||
Public Const EN_R_LE = 2
|
||||
Public Const EN_R_GE = 3
|
||||
Public Const EN_R_LT = 4
|
||||
Public Const EN_R_GT = 5
|
||||
Public Const EN_R_IS = 6
|
||||
Public Const EN_R_NOT = 7
|
||||
Public Const EN_R_BELOW = 8
|
||||
Public Const EN_R_ABOVE = 9
|
||||
|
||||
Public Const EN_R_IS_OPEN = 1 ' Rule status types
|
||||
Public Const EN_R_IS_CLOSED = 2
|
||||
Public Const EN_R_IS_ACTIVE = 3
|
||||
|
||||
'These are the external functions that comprise the DLL
|
||||
|
||||
'System Functions
|
||||
@@ -239,6 +283,8 @@ Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
Declare Function ENgetnodetype Lib "epanet2.dll" (ByVal Index As Int32, ByRef Code As Int32) As Int32
|
||||
Declare Function ENgetnodevalue Lib "epanet2.dll" (ByVal Index As Int32, ByVal Code As Int32, ByRef Value As Single) As Int32
|
||||
Declare Function ENsetnodevalue Lib "epanet2.dll" (ByVal Index As Int32, ByVal Code As Int32, ByVal Value As Single) As Int32
|
||||
Declare Function ENsetjuncdata Lib "epanet2.dll" (ByVal index As Int32, ByVal elev As Single, ByVal dmnd As Single, ByVal dmndpat As String) As Int32
|
||||
Declare Function ENsettankdata Lib "epanet2.dll" (ByVal index As Int32, ByVal elev As Single, ByVal initlvl As Single, ByVal minlvl As Single, ByVal maxlvl As Single, ByVal diam As Single, ByVal minvol As Single, ByVal volcurve As String) As Int32
|
||||
Declare Function ENgetcoord Lib "epanet2.dll" (ByVal Index As Int32, ByRef X As Single, ByRef Y As Single) As Int32
|
||||
Declare Function ENsetcoord Lib "epanet2.dll" (ByVal Index As Int32, ByVal X As Single, ByVal Y As Single) As Int32
|
||||
|
||||
@@ -265,6 +311,7 @@ Public Const EN_CONDITIONAL = 1 ' Conditional object deletion
|
||||
Declare Function ENsetlinknodes Lib "epanet2.dll" (ByVal index As Int32, ByVal node1 As Int32, ByVal node2 As Int32) As Int32
|
||||
Declare Function ENgetlinkvalue Lib "epanet2.dll" (ByVal Index As Int32, ByVal Code As Int32, ByRef Value As Single) As Int32
|
||||
Declare Function ENsetlinkvalue Lib "epanet2.dll" (ByVal Index As Int32, ByVal Code As Int32, ByVal Value As Single) As Int32
|
||||
Declare Function ENsetpipedata Lib "epanet2.dll" (ByVal index As Int32, ByVal length As Single, ByVal diam As Single, ByVal rough As Single, ByVal mloss As Single) As Int32
|
||||
|
||||
'Pump Functions
|
||||
Declare Function ENgetheadcurveindex Lib "epanet2.dll" (ByVal Index As Int32, ByVal CurveIndex As int32) As Int32 'ES
|
||||
|
||||
@@ -11,7 +11,7 @@
|
||||
Authors: see AUTHORS
|
||||
Copyright: see AUTHORS
|
||||
License: see LICENSE
|
||||
Last Updated: 11/29/2018
|
||||
Last Updated: 12/31/2018
|
||||
******************************************************************************
|
||||
*/
|
||||
|
||||
@@ -46,22 +46,14 @@
|
||||
#endif // __cplusplus
|
||||
#elif defined(CYGWIN)
|
||||
#define DLLEXPORT __stdcall
|
||||
#elif defined(__APPLE__)
|
||||
#ifdef __cplusplus
|
||||
#define DLLEXPORT
|
||||
#else
|
||||
#define DLLEXPORT
|
||||
#endif
|
||||
#else
|
||||
#define DLLEXPORT
|
||||
#endif
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
||||
#include "epanet2_enums.h"
|
||||
|
||||
|
||||
// --- Declare the EPANET toolkit functions
|
||||
#if defined(__cplusplus)
|
||||
extern "C" {
|
||||
@@ -137,6 +129,12 @@ typedef struct Project *EN_Project;
|
||||
int DLLEXPORT EN_getnodetype(EN_Project ph, int index, int *code);
|
||||
int DLLEXPORT EN_getnodevalue(EN_Project ph, int index, int code, EN_API_FLOAT_TYPE *value);
|
||||
int DLLEXPORT EN_setnodevalue(EN_Project ph, int index, int code, EN_API_FLOAT_TYPE v);
|
||||
int DLLEXPORT EN_setjuncdata(EN_Project ph, int index, EN_API_FLOAT_TYPE elev,
|
||||
EN_API_FLOAT_TYPE dmnd, char *dmndpat);
|
||||
int DLLEXPORT EN_settankdata(EN_Project ph, int index, EN_API_FLOAT_TYPE elev,
|
||||
EN_API_FLOAT_TYPE initlvl, EN_API_FLOAT_TYPE minlvl,
|
||||
EN_API_FLOAT_TYPE maxlvl, EN_API_FLOAT_TYPE diam,
|
||||
EN_API_FLOAT_TYPE minvol, char *volcurve);
|
||||
int DLLEXPORT EN_getcoord(EN_Project ph, int index, EN_API_FLOAT_TYPE *x,
|
||||
EN_API_FLOAT_TYPE *y);
|
||||
int DLLEXPORT EN_setcoord(EN_Project ph, int index, EN_API_FLOAT_TYPE x,
|
||||
@@ -173,6 +171,9 @@ typedef struct Project *EN_Project;
|
||||
int DLLEXPORT EN_getlinkvalue(EN_Project ph, int index, EN_LinkProperty code,
|
||||
EN_API_FLOAT_TYPE *value);
|
||||
int DLLEXPORT EN_setlinkvalue(EN_Project ph, int index, int code, EN_API_FLOAT_TYPE v);
|
||||
int DLLEXPORT EN_setpipedata(EN_Project ph, int index, EN_API_FLOAT_TYPE length,
|
||||
EN_API_FLOAT_TYPE diam, EN_API_FLOAT_TYPE rough, EN_API_FLOAT_TYPE mloss);
|
||||
|
||||
|
||||
int DLLEXPORT EN_getpumptype(EN_Project ph, int linkIndex, int *outType);
|
||||
int DLLEXPORT EN_getheadcurveindex(EN_Project ph, int pumpIndex, int *curveIndex);
|
||||
|
||||
@@ -7,7 +7,7 @@
|
||||
Authors: see AUTHORS
|
||||
Copyright: see AUTHORS
|
||||
License: see LICENSE
|
||||
Last Updated: 11/29/2018
|
||||
Last Updated: 01/01/2019
|
||||
******************************************************************************
|
||||
*/
|
||||
|
||||
@@ -69,13 +69,14 @@ typedef enum {
|
||||
EN_ENERGY = 13, //!> Current pump energy usage
|
||||
EN_LINKQUAL = 14, //!> Current link quality
|
||||
EN_LINKPATTERN = 15, //!> Pump speed time pattern
|
||||
EN_EFFICIENCY = 16, //!> Current pump efficiency
|
||||
EN_HEADCURVE = 17, //!> Pump head v. flow curve
|
||||
EN_EFFICIENCYCURVE = 18, //!> Pump efficiency v. flow curve
|
||||
EN_PRICEPATTERN = 19, //!> Pump energy price time pattern
|
||||
EN_STATE = 20, //!> Current pump status
|
||||
EN_CONST_POWER = 21, //!> Horsepower of constant horsepower pump
|
||||
EN_SPEED = 22 //!> Current pump speed setting
|
||||
|
||||
EN_PUMP_STATE = 16, //!> Current pump status
|
||||
EN_PUMP_EFFIC = 17, //!> Current pump efficiency
|
||||
EN_PUMP_POWER = 18, //!> Pump constant power rating
|
||||
EN_PUMP_HCURVE = 19, //!> Pump head v. flow curve
|
||||
EN_PUMP_ECURVE = 20, //!> Pump efficiency v. flow curve
|
||||
EN_PUMP_ECOST = 21, //!> Pump average energy price
|
||||
EN_PUMP_EPAT = 22 //!> Pump energy price time pattern
|
||||
} EN_LinkProperty;
|
||||
|
||||
/// Time parameter codes
|
||||
@@ -181,17 +182,21 @@ typedef enum {
|
||||
EN_PDA = 1 //!< Pressure driven analysis
|
||||
} EN_DemandModel;
|
||||
|
||||
/// Simulation Option codes
|
||||
/// Simulation option codes
|
||||
typedef enum {
|
||||
EN_TRIALS = 0, //!> Maximum hydraulic trials allowed
|
||||
EN_ACCURACY = 1, //!> Hydraulic convergence accuracy
|
||||
EN_TOLERANCE = 2, //!> Water quality tolerance
|
||||
EN_EMITEXPON = 3, //!> Exponent for emitter head loss formula
|
||||
EN_DEMANDMULT = 4, //!> Global demand multiplier
|
||||
EN_HEADERROR = 5, //!> Maximum allowable head loss error
|
||||
EN_FLOWCHANGE = 6, //!> Maximum allowable flow change
|
||||
EN_DEMANDDEFPAT = 7, //!> Default demand time pattern
|
||||
EN_HEADLOSSFORM = 8 //!> Head loss formula code
|
||||
EN_TRIALS = 0, //!> Maximum hydraulic trials allowed
|
||||
EN_ACCURACY = 1, //!> Hydraulic convergence accuracy
|
||||
EN_TOLERANCE = 2, //!> Water quality tolerance
|
||||
EN_EMITEXPON = 3, //!> Exponent for emitter head loss formula
|
||||
EN_DEMANDMULT = 4, //!> Global demand multiplier
|
||||
EN_HEADERROR = 5, //!> Maximum allowable head loss error
|
||||
EN_FLOWCHANGE = 6, //!> Maximum allowable flow change
|
||||
EN_DEFDEMANDPAT = 7, //!> Default demand time pattern
|
||||
EN_HEADLOSSFORM = 8, //!> Head loss formula code
|
||||
EN_GLOBALEFFIC = 9, //!> Global pump efficiency
|
||||
EN_GLOBALPRICE = 10, //!> Global energy price per KWH
|
||||
EN_GLOBALPATTERN = 11, //!> Global energy price pattern
|
||||
EN_DEMANDCHARGE = 12 //!> Energy charge per max. KW usage
|
||||
} EN_Option;
|
||||
|
||||
/// Simple control types
|
||||
@@ -236,19 +241,26 @@ typedef enum {
|
||||
|
||||
/// Data curve types
|
||||
typedef enum {
|
||||
EN_V_CURVE = 0, //!< Tank volume curve
|
||||
EN_P_CURVE = 1, //!< Pump characteristic curve
|
||||
EN_E_CURVE = 2, //!< Pump efficiency curve
|
||||
EN_H_CURVE = 3, //!< Valve head loss curve
|
||||
EN_G_CURVE = 4 //!< General\default curve
|
||||
EN_VOLUME_CURVE = 0, //!< Tank volume curve
|
||||
EN_PUMP_CURVE = 1, //!< Pump head curve
|
||||
EN_EFFIC_CURVE = 2, //!< Pump efficiency curve
|
||||
EN_HLOSS_CURVE = 3, //!< Valve head loss curve
|
||||
EN_GENERIC_CURVE = 4 //!< Generic curve
|
||||
} EN_CurveType;
|
||||
|
||||
/// Deletion action types
|
||||
/// Deletion action codes
|
||||
typedef enum {
|
||||
EN_UNCONDITIONAL = 0, //!> Delete all controls that contain object
|
||||
EN_CONDITIONAL = 1 //!> Cancel object deletion if contained in controls
|
||||
} EN_ActionCodeType;
|
||||
|
||||
/// Status report options
|
||||
typedef enum {
|
||||
EN_NO_REPORT = 0,
|
||||
EN_NORMAL_REPORT = 1,
|
||||
EN_FULL_REPORT = 2
|
||||
} EN_StatusReport;
|
||||
|
||||
/// Rule object codes
|
||||
typedef enum {
|
||||
EN_R_NODE = 6,
|
||||
@@ -294,12 +306,5 @@ typedef enum {
|
||||
EN_R_IS_ACTIVE = 3
|
||||
} EN_RuleStatus;
|
||||
|
||||
/// Status report types
|
||||
typedef enum {
|
||||
EN_NO_REPORT = 0,
|
||||
EN_NORMAL_REPORT = 1,
|
||||
EN_FULL_REPORT = 2
|
||||
} EN_StatusReport;
|
||||
|
||||
|
||||
#endif //EPANET2_ENUMS_H
|
||||
|
||||
Reference in New Issue
Block a user