@@ -60,9 +60,9 @@ typedef enum {
EN_TANK_KBULK = 23, //!< Tank bulk decay coefficient
EN_TANKVOLUME = 24, //!< Current computed tank volume (read only)
EN_MAXVOLUME = 25, //!< Tank maximum volume (read only)
EN_CANOVERFLOW = 26, //!< Tank can overflow (= 1) or not (= 0)
EN_CANOVERFLOW = 26, //!< `EN_TRUE` (= 1) if the Tank can overflow, `EN_FALSE` (= 0) if it cannot
EN_DEMANDDEFICIT = 27,//!< Amount that full demand is reduced under PDA (read only)
EN_NODE_INCONTROL = 28, //!< Is present in any simple or rule-based control (= 1) or not (= 0)
EN_NODE_INCONTROL = 28, //!< `EN_TRUE` (= 1) if the node appears in any control, `EN_FALSE` (= 0) if not
EN_EMITTERFLOW = 29, //!< Current emitter flow (read only)
EN_LEAKAGEFLOW = 30, //!< Current leakage flow (read only)
EN_DEMANDFLOW = 31, //!< Current consumer demand delivered (read only)
@@ -81,7 +81,7 @@ typedef enum {
EN_MINORLOSS = 3, //!< Pipe/valve minor loss coefficient
EN_INITSTATUS = 4, //!< Initial status (see @ref EN_LinkStatusType)
EN_INITSETTING = 5, //!< Initial pump speed or valve setting
EN_KBULK = 6, //!< Bulk chemical reaction coefficient
EN_KBULK = 6, //!< Bulk flow chemical reaction coefficient
EN_KWALL = 7, //!< Pipe wall chemical reaction coefficient
EN_FLOW = 8, //!< Current computed flow rate (read only)
EN_VELOCITY = 9, //!< Current computed flow velocity (read only)
@@ -100,7 +100,7 @@ typedef enum {
EN_PUMP_EPAT = 22, //!< Pump energy price time pattern index
EN_LINK_INCONTROL = 23, //!< Is present in any simple or rule-based control (= 1) or not (= 0)
EN_GPV_CURVE = 24, //!< GPV head loss v. flow curve index
EN_PCV_CURVE = 25, //!< PCV loss coeff. curve index
EN_PCV_CURVE = 25, //!< PCV characteristic curve index
EN_LEAK_AREA = 26, //!< Pipe leak area (sq mm per 100 length units)
EN_LEAK_EXPAN = 27, //!< Leak expansion rate (sq mm per unit of pressure head)
EN_LINK_LEAKAGE = 28, //!< Current leakage rate (read only)
@@ -222,8 +222,8 @@ initial status (`EN_INITSTATUS`) or its current status (`EN_STATUS`). These opti
also used with @ref EN_setlinkvalue to set values for these same properties.
*/
typedef enum {
EN_CLOSED = 0,
EN_OPEN = 1
EN_CLOSED = 0, //!< Link is closed and cannot convey any flow
EN_OPEN = 1 //!< Link is open and is able to convey flow
} EN_LinkStatusType;
/// Pump states
@@ -357,7 +357,7 @@ typedef enum {
EN_TANKORDER = 21, //!< Bulk water reaction order for tanks
EN_CONCENLIMIT = 22, //!< Limiting concentration for growth reactions
EN_DEMANDPATTERN = 23, //!< Name of default demand pattern
EN_EMITBACKFLOW = 24, //!< 1 if emitters can backflow, 0 if not
EN_EMITBACKFLOW = 24, //!< `EN_TRUE` (= 1) if emitters can backflow, `EN_FALSE` (= 0) if not
EN_PRESS_UNITS = 25, //!< Pressure units (see @ref EN_PressUnits)
EN_STATUS_REPORT = 26 //!< Type of status report to produce (see @ref EN_StatusReport)