Add emitter backflow option

Adds a global hydraulic option to allow backflow or not through emitter elements. To maintain backward compatibility the default is YES.
This commit is contained in:
Lew Rossman
2023-02-05 15:16:20 -05:00
parent 9814564e29
commit 847fa82139
13 changed files with 55 additions and 10 deletions

View File

@@ -9,7 +9,7 @@
Authors: see AUTHORS
Copyright: see AUTHORS
License: see LICENSE
Last Updated: 08/13/2022
Last Updated: 02/05/2023
******************************************************************************
*/
@@ -335,7 +335,8 @@ typedef enum {
EN_WALLORDER = 20, //!< Wall reaction order for pipes (either 0 or 1)
EN_TANKORDER = 21, //!< Bulk water reaction order for tanks
EN_CONCENLIMIT = 22, //!< Limiting concentration for growth reactions
EN_DEMANDPATTERN = 23 //!< Name of default demand pattern
EN_DEMANDPATTERN = 23, //!< Name of default demand pattern
EN_EMITBACKFLOW = 24 //!< 1 if emitters can backflow, 0 if not
} EN_Option;
/// Simple control types