Updates documentation with newly added functions
This commit is contained in:
@@ -178,6 +178,9 @@ Both network files are available [here](https://doi.org/10.23719/1375314).
|
||||
|`EN_getelseaction`|Gets the contents of an ELSE action in a rule-based control|
|
||||
|`EN_setelseaction`|Set the contents of an ELSE action in a rule-based control|
|
||||
|`EN_setrulepriority`|Sets the priority of a rule-based control|
|
||||
|`EN_gettitle` |Gets a project's title |
|
||||
|`EN_settitle` |Sets a project's title |
|
||||
|`EN_clearreport` |Clears the contents of a project's report file |
|
||||
In addition to these new functions, a tank's volume curve `EN_VOLCURVE` can be set using `EN_setnodevalue` and `EN_setlinkvalue` can now be used to set the following pump properties:
|
||||
- `EN_PUMP_POWER` (constant power rating)
|
||||
- `EN_PUMP_HCURVE` (head characteristic curve)
|
||||
|
||||