Allow simple controls to set valves OPEN/CLOSED

This commit is contained in:
Lew Rossman
2023-05-13 12:29:35 -04:00
parent 583cca01ca
commit a9079b023b
10 changed files with 155 additions and 139 deletions

View File

@@ -7,7 +7,7 @@
Authors: see AUTHORS
Copyright: see AUTHORS
License: see LICENSE
Last Updated: 08/13/2022
Last Updated: 04/29/2023
******************************************************************************
*/
@@ -1121,6 +1121,111 @@ int resizecurve(Scurve *curve, int size)
return 0;
}
int setcontrol(EN_Project p, int type, int linkIndex, double setting,
int nodeIndex, double level, Scontrol *control)
/*----------------------------------------------------------------
** Input: type = type of control (see EN_ControlType)
** linkIndex = index of link being controlled
** setting = link control setting (e.g., pump speed)
** nodeIndex = index of node controlling a link (for level controls)
** level = control activation level (pressure for junction nodes,
** water level for tank nodes or time value for time-based
** control)
** Output: control = control struct whose properties are being set
** Returns: error code
** Purpose: assigns properties to a control struct.
**----------------------------------------------------------------
*/
{
Network *net = &p->network;
Parser *parser = &p->parser;
long t = 0;
double lvl = 0.0, s = MISSING;
double *Ucf = p->Ucf;
LinkType linktype;
StatusType status = ACTIVE;
// Cannot control check valve
linktype = net->Link[linkIndex].Type;
if (linktype == CVPIPE) return 207;
// Check for valid control type and node index
if (type < 0 || type > TIMEOFDAY) return 251;
if (type == LOWLEVEL || type == HILEVEL)
{
if (nodeIndex < 1 || nodeIndex > net->Nnodes) return 203;
}
else nodeIndex = 0;
// Check if control setting is a status level
if (setting == SET_OPEN)
{
status = OPEN;
if (linktype == PUMP) s = 1.0;
if (linktype == GPV) s = net->Link[linkIndex].Kc;
}
else if (setting == SET_CLOSED)
{
status = CLOSED;
if (linktype == PUMP) s = 0.0;
if (linktype == GPV) s = net->Link[linkIndex].Kc;
}
// Convert units of control setting
else
{
s = setting;
switch (linktype)
{
case PIPE:
case PUMP:
if (s < 0.0) return 202;
else if (s == 0.0) status = CLOSED;
else status = OPEN;
break;
case PRV:
case PSV:
case PBV:
s /= Ucf[PRESSURE];
break;
case FCV:
s /= Ucf[FLOW];
break;
case GPV:
if (s == 0.0) status = CLOSED;
else if (s == 1.0) status = OPEN;
else return 202;
s = net->Link[linkIndex].Kc;
break;
}
}
// Determine if control level is a pressure, tank level or time value
if (type == LOWLEVEL || type == HILEVEL)
{
if (nodeIndex > net->Njuncs) lvl = net->Node[nodeIndex].El + level / Ucf[ELEV];
else lvl = net->Node[nodeIndex].El + level / Ucf[PRESSURE];
}
else if (type == TIMER || type == TIMEOFDAY)
{
t = (long)level;
if (t < 0) return 202;
}
// Assign values to control struct
control->Link = linkIndex;
control->Node = nodeIndex;
control->Type = type;
control->Status = status;
control->Setting = s;
control->Time = t;
control->Grade = lvl;
return 0;
}
int getcomment(Network *network, int object, int index, char *comment)
//----------------------------------------------------------------