@@ -4177,8 +4177,7 @@ int DLLEXPORT EN_setlinkvalue(EN_Project p, int index, int property, double valu
{
Link[index].Kc = value;
Link[index].InitSetting = value;
valveType = Link[index].Type;
if (valveType > PUMP && valveType != GPV)
if (Link[index].Type > PUMP && Link[index].Type != GPV)
{
Link[index].InitStatus = ACTIVE;
}
@@ -4343,8 +4342,12 @@ int DLLEXPORT EN_setpipedata(EN_Project p, int index, double length,
if (p->hydraul.Formflag == DW) Link[index].Kc /= (1000.0 * Ucf[ELEV]);
// Update minor loss factor & pipe flow resistance
Link[index].Km = 0.02517 * mloss / SQR(Link[index].Diam) / SQR(Link[index].Diam);
resistcoeff(p, index);
if (p->hydraul.OpenHflag)
{
Link[index].Km = 0.02517 * mloss / SQR(Link[index].Diam) / SQR(Link[index].Diam);
resistcoeff(p, index);
}
else Link[index].InitSetting = Link[index].Kc;
return 0;
}