This update prevents a solution where the computed loss coefficient for a FCV at its flow setting would be less than the user supplied fully opened coefficient.
Improves the way link flow into full and out of empty tanks is checked. Also corrects the head loss and gradient calculation for constant horsepower pumps at very low and very high flow rates (this was affecting one of the examples used to test the full/empty tank fix).
This commit removes the #ifdef _DEBUG statements at the top of all source code files per issue #482. It also updates the doc files to stress that the speedup observed for hydraulic analysis with the MMD node re-ordering method only applies to single period runs.
1. Added a standard header to each code module and removed obsolete comments.
2. Re-named several of the sub-structs in the project struct and re-arranged some of their contents.
3. Re-named _defaultModel to _defaultProject.
4. Removed the need to call EN_createproject and EN_deleteproject when working with the default project.
5. Made X & Y coords. part of Snode properties instead of a separate struct.
6. Moved the non-API functions in epanet.c into a new module named project.c.
7. Re-factored the quality module so that it uses the same nodal adjacency lists as the hydraulics solver.
8. Re-factored the sparse matrix module (smatrix.c) to be more memory efficient.
9. Restricted line lengths to < 90 columns.
10. Grouped the placement of functions in EPANET2.H and EPANET.C by category.
- Deleting controls with node/link deletion made conditional.
- New EN_addrule function added along with a test file.
- Rule structures re-named & rules.c heavily modified.
- Issue with exceeding limit on number of temporary file names fixed.
- VB declaration and DEF files updated.