Page 1 Fri Mar 23 14:48:34 2018 ****************************************************************** * E P A N E T * * Hydraulic and Water Quality * * Analysis for Pipe Networks * * Version 2.00.12 * ****************************************************************** JEPPSON EXAMPLE V-13 Input Data File ................... JEP5-13.inp Number of Junctions................ 8 Number of Reservoirs............... 2 Number of Tanks ................... 0 Number of Pipes ................... 10 Number of Pumps ................... 0 Number of Valves .................. 2 Headloss Formula .................. Darcy-Weisbach Hydraulic Timestep ................ 1.00 hrs Hydraulic Accuracy ................ 0.001000 Status Check Frequency ............ 2 Maximum Trials Checked ............ 10 Damping Limit Threshold ........... 0.000000 Maximum Trials .................... 200 Quality Analysis .................. None Specific Gravity .................. 1.00 Relative Kinematic Viscosity ...... 1.00 Relative Chemical Diffusivity ..... 1.00 Demand Multiplier ................. 1.00 Total Duration .................... 0.00 hrs Reporting Criteria: No Nodes No Links Analysis begun Fri Mar 23 14:48:34 2018 Hydraulic Status: ----------------------------------------------------------------------- 0:00:00: Balancing the network: Trial 1: relative flow change = 0.991580 Trial 2: relative flow change = 0.903818 PRV 801 switched from active to closed Trial 3: relative flow change = 1.337354 Trial 4: relative flow change = 0.511944 PRV 701 switched from active to closed Trial 5: relative flow change = 0.154394 PRV 701 switched from closed to active PRV 801 switched from closed to active Trial 6: relative flow change = 0.991636 Trial 7: relative flow change = 0.996578 PRV 701 switched from active to open PRV 801 switched from active to closed Trial 8: relative flow change = 2.547310 PRV 701 switched from open to active Trial 9: relative flow change = 0.845271 PRV 701 switched from active to open Trial 10: relative flow change = 1.123269 PRV 701 switched from open to active Trial 11: relative flow change = 0.787941 PRV 701 switched from active to open PRV 801 switched from closed to open Trial 12: relative flow change = 1.200130 PRV 701 switched from open to active PRV 801 switched from open to closed Trial 13: relative flow change = 0.741413 PRV 701 switched from active to open PRV 801 switched from closed to active Trial 14: relative flow change = 1.164079 PRV 701 switched from open to active Trial 15: relative flow change = 0.834667 PRV 801 switched from active to closed Trial 16: relative flow change = 0.822158 Trial 17: relative flow change = 0.480614 Trial 18: relative flow change = 0.316797 Trial 19: relative flow change = 0.085031 Trial 20: relative flow change = 0.015071 Trial 21: relative flow change = 0.001529 Trial 22: relative flow change = 0.000119 0:00:00: Balanced after 22 trials 0:00:00: Reservoir 101 is emptying 0:00:00: Reservoir 102 is filling 0:00:00: PRV 801 closed Analysis ended Fri Mar 23 14:48:34 2018