Files
EPANET/tests/epanet-nrtestsuite/benchmark/epanet-2012/fcv-noflow/fcv-noflow.rpt
2018-04-02 11:33:11 -04:00

33 lines
1.5 KiB
Plaintext

Page 1 Fri Mar 23 14:48:38 2018
******************************************************************
* E P A N E T *
* Hydraulic and Water Quality *
* Analysis for Pipe Networks *
* Version 2.00.12 *
******************************************************************
Analysis begun Fri Mar 23 14:48:38 2018
Hydraulic Status:
-----------------------------------------------------------------------
0:00:00: Balancing the network:
Trial 1: relative flow change = 1.115389
Trial 2: relative flow change = 1.173709
Trial 3: relative flow change = 1.173711
Trial 4: relative flow change = 1.173708
Trial 5: relative flow change = 1.173715
Trial 6: relative flow change = 1.173713
Trial 7: relative flow change = 1.173725
Trial 8: relative flow change = 1.173760
Trial 9: relative flow change = 1.173731
Trial 10: relative flow change = 1.173601
Trial 11: relative flow change = 1.173730
Trial 12: relative flow change = 0.000669
0:00:00: Balanced after 12 trials
0:00:00: Reservoir R1 is closed
0:00:00: Reservoir R2 is closed
Analysis ended Fri Mar 23 14:48:38 2018