fix(api): align frontend with project-scoped backend
Use project-scoped endpoints and run IDs for current project, SCADA metadata, historical time series, migrated DMA results, and sensor placement runs. The regressions recurred because tests mocked pre-interceptor and new-only payload shapes, while history queries relied on implicit global scheme state and unbounded request fan-out. Cover post-interceptor pages, migrated result_rows, explicit run_id routing, multi-element requests, request limits, and cancellation.
This commit is contained in:
@@ -1,12 +1,26 @@
|
||||
import dayjs from "dayjs";
|
||||
import { api } from "@/lib/api";
|
||||
import {
|
||||
buildBurstDetectionRequest,
|
||||
createBurstDetectionAnalysisParametersState,
|
||||
fetchPressureSamplingInterval,
|
||||
parseScadaFrequencyMinutes,
|
||||
resolvePressureSamplingInterval,
|
||||
} from "./AnalysisParameters";
|
||||
|
||||
jest.mock("@/lib/api", () => ({
|
||||
api: {
|
||||
get: jest.fn(),
|
||||
},
|
||||
}));
|
||||
|
||||
const get = api.get as jest.Mock;
|
||||
|
||||
describe("burst detection request", () => {
|
||||
beforeEach(() => {
|
||||
get.mockReset();
|
||||
});
|
||||
|
||||
it("requests the latest complete monitoring time by default", () => {
|
||||
const state = createBurstDetectionAnalysisParametersState();
|
||||
state.schemeName = " latest-case ";
|
||||
@@ -45,11 +59,27 @@ describe("burst detection request", () => {
|
||||
expect(parseScadaFrequencyMinutes("1:00:00")).toBe(60);
|
||||
expect(
|
||||
resolvePressureSamplingInterval([
|
||||
{ type: "pressure", transmission_frequency: "0:15:00" },
|
||||
{ type: "pressure", transmission_frequency: "0:15:00" },
|
||||
{ type: "pressure", transmission_frequency: "0:30:00" },
|
||||
{ type: "pipe_flow", transmission_frequency: "1:00:00" },
|
||||
{ device_type: "pressure", transmission_frequency: "0:15:00" },
|
||||
{ device_type: "pressure", transmission_frequency: "0:15:00" },
|
||||
{ device_type: "pressure", transmission_frequency: "0:30:00" },
|
||||
{ device_type: "pipe_flow", transmission_frequency: "1:00:00" },
|
||||
]),
|
||||
).toBe(15);
|
||||
});
|
||||
|
||||
it("loads the pressure frequency from the pooled SCADA metadata endpoint", async () => {
|
||||
get.mockResolvedValue({
|
||||
data: {
|
||||
success: true,
|
||||
count: 2,
|
||||
data: [
|
||||
{ device_type: "pressure", transmission_frequency: "0:30:00" },
|
||||
{ device_type: "pipe_flow", transmission_frequency: "0:15:00" },
|
||||
],
|
||||
},
|
||||
});
|
||||
|
||||
await expect(fetchPressureSamplingInterval()).resolves.toBe(30);
|
||||
expect(get).toHaveBeenCalledWith("/api/v1/scada-info/database-view");
|
||||
});
|
||||
});
|
||||
|
||||
Reference in New Issue
Block a user