feat: align frontend runtime and Edge TTS

This commit is contained in:
2026-07-22 15:01:25 +08:00
parent d2c278f0ea
commit 699a0bced4
43 changed files with 2000 additions and 73 deletions
@@ -92,7 +92,7 @@ const CONDITION_TASKS: ConditionTaskDefinition[] = [
{
id: "pump-energy",
title: "泵站能耗检查",
summary: "检查泵组负载、单位排水电耗、启停频率和供压稳定性。",
summary: "检查泵组负载、单位供水电耗、启停频率和供压稳定性。",
intervalMinutes: 60,
durationMinutes: 10
}
@@ -709,16 +709,16 @@ function createTaskKpis(task: ConditionTaskDefinition, signal: TaskSignal): Sche
return [
{
id: "energy-deviation",
label: "单位排水电耗偏差",
label: "单位供水电耗偏差",
value: energyDeviation.toString(),
unit: "%",
threshold: "关注 > 10%,异常 > 15%",
status: getMetricRisk(energyDeviation, 10, 15),
description: "本轮单位排水电耗相对同窗基线的偏差。"
description: "本轮单位供水电耗相对同窗基线的偏差。"
},
{
id: "unit-energy",
label: "单位排水电耗",
label: "单位供水电耗",
value: unitEnergy.toString(),
unit: "kWh/m3",
baseline: "同窗经济运行区间 0.28-0.34",
@@ -780,10 +780,10 @@ function createDispatchInstructions(signal: TaskSignal): DispatchInstruction[] {
action: "泵组组合优化",
target: "1# 泵站 3# / 4# 泵组",
command: "保持 3# 泵运行,延后 4# 泵启动 10 分钟,避免低效并联区间",
verification: "复核单位排水电耗是否低于 0.34kWh/m3"
verification: "复核单位供水电耗是否低于 0.34kWh/m3"
},
{
action: "高区排水边界收敛",
action: "高区供水边界收敛",
target: "高区联络阀 HV-204",
command: "开度下调 3%,减少高区向中区回流",
verification: "确认高区末端压力不低于 0.22MPa"
@@ -819,7 +819,7 @@ function createDispatchInstructions(signal: TaskSignal): DispatchInstruction[] {
{
action: "阀门开度回退",
target: "华山路沿线阀门组 VG-11",
command: "将昨日临时开度回退 2%,恢复常规排水边界",
command: "将昨日临时开度回退 2%,恢复常规供水边界",
verification: "观察华山路和人民路支线压差不超过 2.5m"
},
{
@@ -911,7 +911,7 @@ function createGuidanceItems(
if (task.id === "pump-energy") {
return [
"关注单位排水电耗和启停频率,判断是否存在泵组组合不经济。",
"关注单位供水电耗和启停频率,判断是否存在泵组组合不经济。",
"若电耗偏差持续升高,建议比较相邻泵组效率曲线并优化启停策略。",
"调整前需确认供压稳定性,避免节能动作引发末端低压。"
];