Files
next-tjwater-server/scripts/check_burst_simulation_design.py
T

289 lines
12 KiB
Python

#!/usr/bin/env python3
"""Read-only validation of the tjwater2_v2 burst-simulation design."""
from __future__ import annotations
import argparse
import asyncio
import sys
import traceback
from datetime import timedelta
from pathlib import Path
from psycopg import connect
from psycopg.conninfo import conninfo_to_dict, make_conninfo
from psycopg.rows import dict_row
def readonly(dsn: str):
return connect(
make_conninfo(
dsn,
options="-c default_transaction_read_only=on -c statement_timeout=20000",
application_name="tjwater-burst-design-readonly",
connect_timeout="5",
),
row_factory=dict_row,
)
async def resolve_project(design):
from sqlalchemy import text
from app.infra.db.metadb.database import SessionLocal, engine
from app.infra.db.metadb.repositories.metadata_repository import MetadataRepository
try:
async with SessionLocal() as session:
await session.execute(
text("SET TRANSACTION ISOLATION LEVEL REPEATABLE READ, READ ONLY")
)
repo = MetadataRepository(session)
project = await repo.get_project_by_code(design.project_code)
if (
project is None
or project.id != design.project_id
or project.status != "active"
):
raise ValueError("project identity or active status does not match")
biz = await repo.get_project_db_routing(project.id, "biz_data")
iot = await repo.get_project_db_routing(project.id, "iot_data")
if biz is None or iot is None:
raise ValueError("project database routing is incomplete")
await session.rollback()
return biz.dsn, iot.dsn
finally:
await engine.dispose()
def validate_database(connection, design, *, template: bool) -> None:
connection.execute("SET TRANSACTION ISOLATION LEVEL REPEATABLE READ, READ ONLY")
if connection.execute("SHOW transaction_read_only").fetchone()["transaction_read_only"] != "on":
raise ValueError("database transaction is not read-only")
expected = design.model_expectations
counts = connection.execute(
"SELECT (SELECT count(*) FROM network.nodes) AS nodes, "
"(SELECT count(*) FROM network.pipes) AS pipes, "
"(SELECT count(*) FROM network.links WHERE link_type='valve') AS valves"
).fetchone()
if (counts["nodes"], counts["pipes"], counts["valves"]) != (
expected.node_count,
expected.pipe_count,
expected.valve_count,
):
raise ValueError("model counts do not match the frozen design")
settings = {
row["key"]: row["value"]
for row in connection.execute(
"SELECT key,value FROM network.simulation_settings "
"WHERE engine_version='legacy' AND key=ANY(%s)",
(["UNITS", "PRESSURE", "EMITTER EXPONENT"],),
)
}
times = {
row["key"]: row["value"]
for row in connection.execute(
"SELECT key,value FROM network.time_settings "
"WHERE key=ANY(%s)",
(["HYDRAULIC TIMESTEP", "REPORT TIMESTEP"],),
)
}
if settings != {
"UNITS": expected.flow_unit,
"PRESSURE": expected.pressure_unit,
"EMITTER EXPONENT": f"{expected.emitter_exponent:.4f}",
}:
raise ValueError("simulation settings do not match the frozen design")
if times != {"HYDRAULIC TIMESTEP": "0:15:00", "REPORT TIMESTEP": "0:15:00"}:
raise ValueError("simulation timesteps do not match the frozen design")
for pipe in design.pipes:
row = connection.execute(
"SELECT l.start_node_id,l.end_node_id,p.length,p.diameter,p.status "
"FROM network.links l JOIN network.pipes p ON p.link_id=l.id WHERE l.id=%s",
(pipe.pipe_id,),
).fetchone()
if row is None:
raise ValueError(f"pipe {pipe.pipe_id} is missing")
if (
str(row["start_node_id"]) != pipe.start_node_id
or str(row["end_node_id"]) != pipe.emitter_node_id
or abs(float(row["length"]) - pipe.length_m) > 0.001
or abs(float(row["diameter"]) - pipe.diameter_mm) > 0.001
or str(row["status"]).upper() != "OPEN"
):
raise ValueError(f"pipe {pipe.pipe_id} properties changed")
node_rows = connection.execute(
"SELECT id,node_type FROM network.nodes WHERE id=ANY(%s)",
(pipe.output_node_ids,),
).fetchall()
if {str(row["id"]) for row in node_rows} != set(pipe.output_node_ids):
raise ValueError(f"pipe {pipe.pipe_id} output nodes are incomplete")
node_types = {str(row["id"]): str(row["node_type"]) for row in node_rows}
if node_types.get(pipe.emitter_node_id) != "junction":
raise ValueError(f"pipe {pipe.pipe_id} emitter endpoint is not a junction")
link_rows = connection.execute(
"SELECT id,link_type FROM network.links WHERE id=ANY(%s)",
(pipe.output_link_ids,),
).fetchall()
if {str(row["id"]) for row in link_rows} != set(pipe.output_link_ids):
raise ValueError(f"pipe {pipe.pipe_id} output links are incomplete")
link_types = {str(row["id"]): str(row["link_type"]) for row in link_rows}
if any(link_types.get(value) != "valve" for value in pipe.boundary_valve_ids):
raise ValueError(f"pipe {pipe.pipe_id} boundary valve changed")
emitter = connection.execute(
"SELECT coefficient FROM network.emitters WHERE junction_id=%s",
(pipe.emitter_node_id,),
).fetchone()
if emitter is not None:
raise ValueError(f"pipe {pipe.pipe_id} endpoint already has an emitter")
if not template:
pressure_bindings = {
(
str(row["device_id"]),
str(row["node_id"]),
str(row["measurement_unit"]),
str(row["transmission_frequency"]),
)
for row in connection.execute(
"SELECT device_id,node_id,measurement_unit,transmission_frequency "
"FROM asset.scada_devices "
"WHERE device_type='pressure' AND device_id=ANY(%s)",
([value.device_id for value in pipe.pressure_bindings],),
)
}
flow_bindings = {
(
str(row["device_id"]),
str(row["link_id"]),
str(row["measurement_unit"]),
str(row["transmission_frequency"]),
)
for row in connection.execute(
"SELECT device_id,link_id,measurement_unit,transmission_frequency "
"FROM asset.scada_devices "
"WHERE device_type IN ('pipe_flow','flow') AND device_id=ANY(%s)",
([value.device_id for value in pipe.flow_bindings],),
)
}
expected_pressure_bindings = {
(
value.device_id,
value.node_id,
expected.pressure_measurement_unit,
str(timedelta(seconds=expected.report_timestep_seconds)),
)
for value in pipe.pressure_bindings
}
expected_flow_bindings = {
(
value.device_id,
value.link_id,
expected.flow_measurement_unit,
str(timedelta(seconds=expected.report_timestep_seconds)),
)
for value in pipe.flow_bindings
}
if pressure_bindings != expected_pressure_bindings:
raise ValueError(f"pipe {pipe.pipe_id} pressure bindings changed")
if flow_bindings != expected_flow_bindings:
raise ValueError(f"pipe {pipe.pipe_id} flow bindings changed")
pressure_distances = {
str(row["device_id"]): row["distance_m"]
for row in connection.execute(
"SELECT d.device_id,ST_Distance(d.geom,n.geom) AS distance_m "
"FROM asset.scada_devices d "
"JOIN gis.node_geometries n ON n.node_id=d.node_id "
"WHERE d.device_id=ANY(%s)",
([value.device_id for value in pipe.pressure_bindings],),
)
}
flow_distances = {
str(row["device_id"]): row["distance_m"]
for row in connection.execute(
"SELECT d.device_id,"
"ST_Distance(d.geom,ST_Transform(p.geom,900914)) AS distance_m "
"FROM asset.scada_devices d "
"JOIN gis.pipes p ON p.id=d.link_id "
"WHERE d.device_id=ANY(%s)",
([value.device_id for value in pipe.flow_bindings],),
)
}
if len(pressure_distances) != len(pipe.pressure_bindings) or any(
distance is None
or float(distance) > design.binding_validation.max_pressure_distance_m
for distance in pressure_distances.values()
):
raise ValueError(f"pipe {pipe.pipe_id} pressure binding geometry changed")
if len(flow_distances) != len(pipe.flow_bindings) or any(
distance is None
or float(distance) > design.binding_validation.max_flow_distance_m
for distance in flow_distances.values()
):
raise ValueError(f"pipe {pipe.pipe_id} flow binding geometry changed")
connection.rollback()
def validate_tool_inputs(design) -> None:
from app.mcp.extended_models import BurstSimulationInput
pipes = {pipe.pipe_id: pipe for pipe in design.pipes}
for case in design.cases:
pipe = pipes[case.pipe_id]
for severity in design.calibration_order:
BurstSimulationInput(
context_handle="benchmark-design-context-handle-0001",
timeout_seconds=240,
start_time=case.occurred_at,
duration=design.duration_seconds,
output_node_ids=pipe.output_node_ids,
output_link_ids=pipe.output_link_ids,
burst_pipe_ids=[pipe.pipe_id],
orifice_areas_cm2=[pipe.candidate_orifice_areas_cm2[severity]],
)
def main() -> int:
parser = argparse.ArgumentParser(description=__doc__)
parser.add_argument(
"--design",
type=Path,
default=Path("resources/benchmarks/tjwater2-v2-burst-simulation.json"),
)
args = parser.parse_args()
sys.path.insert(0, str(Path(__file__).resolve().parents[1]))
try:
from scripts.benchmark.simulation_design import load_simulation_design
design = load_simulation_design(args.design)
validate_tool_inputs(design)
biz_dsn, _ = asyncio.run(resolve_project(design))
physical_name = conninfo_to_dict(biz_dsn).get("dbname")
if not physical_name:
raise ValueError("business route has no database name")
template_dsn = make_conninfo(biz_dsn, dbname=physical_name + "_template")
with readonly(biz_dsn) as connection:
validate_database(connection, design, template=False)
with readonly(template_dsn) as connection:
validate_database(connection, design, template=True)
except Exception as exc:
frames = traceback.extract_tb(exc.__traceback__)
location = frames[-1] if frames else None
suffix = f" at {location.filename}:{location.lineno}" if location else ""
print(f"burst simulation design check failed ({type(exc).__name__}){suffix}", file=sys.stderr)
return 1
maximum_runs = len(design.cases) * len(design.severity_levels)
print(
f"burst simulation design ready: {len(design.pipes)} pipes, "
f"{len(design.cases)} cases, at most {maximum_runs} calibration runs; "
"tool inputs, SCADA bindings, BizDB and model template were read-only verified"
)
return 0
if __name__ == "__main__":
raise SystemExit(main())