Merge pull request #717 from lbutler/update-releasenotes2_3.md
Update ReleaseNote2_3.md
This commit is contained in:
@@ -28,5 +28,17 @@ This document describes the changes and updates that have been made in version 2
|
||||
- A new set of functions have been added to get information about upcoming time step events. Users will now see what type of event is going to cause the end of a time step to occur. See ENtimetonextevent and EN_timetonextevent.
|
||||
- A new set of functions have been added to allow users to set a reporting callback function. The user-supplied function will recieve all output normally directed to the report file.
|
||||
- A `EN_EMITBACKFLOW` option was added that either allows emitters to have reverse flow through them (the default) or not.
|
||||
|
||||
|
||||
- Elevation was not set correctly when using `EN_settankdata` with SI units, this has been fixed.
|
||||
- The `EN_INITSETTING` option in function `EN_getlinkvalue` will return 0 if the setting equals MISSING due to a fixed `OPEN/CLOSED` status.
|
||||
- The functions `EN_getnodevalue` and `EN_getlinkvalue` now includes options `EN_NODE_INCONTROL` and `EN_LINK_INCONTROL` to determine whether a node or link participates in a simple or rule-based control.
|
||||
- Setting a minor loss of zero with `EN_setlinkvalue(ph, index, EN_MINORLOSS, 0)` would raise an error, this has been fixed.
|
||||
- The reporting of unconnected nodes was not displaying correctly, this has been fixed.
|
||||
- A header file for C# has been added.
|
||||
- A new error code `263 - node is not a tank` is returned for when passing a non-tank node index to `EN_settankdata` or `EN_setnodevalue` with option `EN_TANKLEVEL`, `EN_TANKDIAM`, `EN_MINVOLUME`, `EN_VOLCURVE`, `EN_MINLEVEL`, `EN_MAXLEVEL`, `EN_MIXMODEL`, `EN_MIXFRACTION`, `EN_TANK_KBULK` or `EN_CANOVERFLOW`.
|
||||
- The function `EN_saveinpfile` was incorrectly setting simple controls using GPV with the index of their head loss curve instead of their status, this has been fixed.
|
||||
- Added support for Conan dependency manager.
|
||||
- Fix silent Qualflag reset when QUALITY is not NONE and simulation duration is 0 in EPANET input file.
|
||||
- Added support for cubic meters per second flow units.
|
||||
- A simple control with more than 9 input tokens would set the incorrect hour, this has been fixed.
|
||||
- When reading an EPANET inp file, errors in node and link vertex coordinates are ignored.
|
||||
- Non-zero demands are now not included in `[DEMANDS]` when running `EN_saveinpfile`.
|
||||
|
||||
Reference in New Issue
Block a user