@@ -179,14 +179,14 @@ int runConcurrentQuality(EN_Project ph)
|
||||
The @ref EN_getnodevalue and @ref EN_getlinkvalue functions can also be used to retrieve the results of hydraulic and water quality simulations. The computed parameters (and their Toolkit codes) that can be retrieved are as follows:
|
||||
|For Nodes: | For Links: |
|
||||
|------------------------------------ | ----------------------------------------- |
|
||||
|\b EN_DEMAND (total node outflow |\b EN_FLOW (flow rate) |
|
||||
|\b EN_DEMAND (total node outflow) |\b EN_FLOW (flow rate) |
|
||||
|\b EN_HEAD (hydraulic head) |\b EN_VELOCITY (flow velocity) |
|
||||
|\b EN_PRESSURE (pressure) |\b EN_HEADLOSS (head loss) |
|
||||
|\b EN_TANKLEVEL (tank water level) |\b EN_STATUS (link status) |
|
||||
|\b EN_TANKVOLUME (tank water volume) |\b EN_SETTING (pump speed or valve setting)|
|
||||
|\b EN_QUALITY (water quality) |\b EN_ENERGY (pump energy usage) |
|
||||
|\b EN_SOURCEMASS (source mass inflow)|\b EN_PUMP_EFFIC (pump efficiency) |
|
||||
| |\b EN_LINK_LEAKAGE (pipe leakage flow rate |
|
||||
| |\b EN_LINK_LEAKAGE (pipe leakage flow rate)|
|
||||
|
||||
In addition, the following quantities related to a node's outflow can be retrieved:
|
||||
-# EN_FULLDEMAND (consumer demand requested)
|
||||
|
||||
Reference in New Issue