Lew Rossman
a2c0ff7889
Fix trace node id parser error
2023-09-11 18:23:49 -04:00
Lew Rossman
6aa2a21327
Change PCV settings from fraction to percent
2023-08-17 14:54:59 -04:00
0tkl
2f63e513f0
fix potential memory leaks
...
Co-authored-by: Lew Rossman <LRossman@cinci.rr.com >
2023-08-10 12:32:28 +08:00
0tkl
b860f9b16f
add a default value to controlIndex
2023-08-09 15:38:41 +08:00
0tkl
434cd68a23
fix potential deref of a null pointer
2023-08-05 01:20:09 +08:00
Lew Rossman
353ba4eb34
Allow API to get/set type of status report
...
The existing EN_setstatusreport function only allows one to set the level of status reporting and not retrieve this value. A new EN_STATUS_REPORT constant was added, to be used with EN_setoption and EN_getoption, to provide read/write access to the level of status reporting.
2023-07-19 09:15:25 -04:00
Lew Rossman
3acfb6dae3
Added retrieval of emitter flow to the API
2023-07-06 15:35:30 -04:00
Lew Rossman
789d42f248
Merge pull request #732 from OpenWaterAnalytics/dev-controls
...
Allow simple controls to set valves OPEN/CLOSED
2023-06-08 10:37:45 -04:00
Lew Rossman
a9079b023b
Allow simple controls to set valves OPEN/CLOSED
2023-05-13 12:29:35 -04:00
james uber
f709c199bc
correct error in adjustpumpparams() where a curveindex was being used instead of the pump index
2023-04-22 17:40:25 -04:00
james uber
7ae9c28e1a
setlinkvalue missing a break statement
2023-04-15 12:57:01 -04:00
Lew Rossman
583cca01ca
Merge pull request #721 from OpenWaterAnalytics/dev-PDA-coeffs
...
Use barrier functions for PDA & emitters
2023-04-15 11:01:08 -04:00
Luke Butler
9cde32080a
added function updateruleunits
2023-03-30 16:22:58 -04:00
Lew Rossman
9c79a65171
Use barrier functions for PDA & emitters
...
Uses continuous barrier functions to constrain PDA demands and emitter flows to allowable values (see J. Hydroinformatics, 24:697, 2022).
2023-03-29 10:35:14 -04:00
Luke Butler
6bc1efaf1c
Check pressure units in metric are not set to PSI
2023-03-16 16:21:55 -04:00
Luke Butler
4beebbd470
Add EN_PRESS_UNITS to EN_getoption & EN_setoption
2023-03-16 16:13:49 -04:00
Luke Butler
8e68b77f61
Updated outfile to support cubic meters/sec
2023-02-20 10:24:11 -05:00
Luke Butler
843f1f4e37
Added support for cubic meters per second (CMS)
2023-02-20 09:43:42 -05:00
Luke Butler
3856a6310d
Fixes incorrect hour set with >9 input tokens
...
If you create a simple control with nine or more input tokens, the logic skips over assigning the hour variable and EPANET will activate the control at hour zero.
2023-02-15 14:46:39 -05:00
Lew Rossman
847fa82139
Add emitter backflow option
...
Adds a global hydraulic option to allow backflow or not through emitter elements. To maintain backward compatibility the default is YES.
2023-02-05 15:16:20 -05:00
Lew Rossman
869e441fe8
Revise status test for full/empty tanks
...
Simplifies status check for links connected to full/empty tanks and now includes case where link connects two tanks.
2023-02-03 11:29:05 -05:00
Lew Rossman
2f8561632f
Allows string literals as arguments in C++ clients
...
See issue #651 . Also addresses issue #602 .
2023-01-29 12:34:58 -05:00
Lew Rossman
f60102105a
Ignore errors in coords. read from file
...
Ignores errors when reading node & link vertex coordinates from an input file. Also when saving a project to an input file, the [DEMANDS] section only includes non-zero demands.
See issues #603 and #174 .
2023-01-26 12:50:26 -05:00
Elad Salomons
e2df3e87ac
Adding support for VB
...
Also supporting C89 compiler.
2023-01-19 20:45:30 +02:00
Sam Hatchett
2705f8adc1
Merge branch 'dev' into 681-request-additional-api-function-for-getting-finer-grained-time-step-information
2023-01-19 11:52:18 -05:00
Sam Hatchett
736f5ebdd4
updates function signatures to use int-casted enum
2023-01-19 09:50:50 -05:00
Sam Hatchett
30c511ca78
Merge branch 'dev' into 683-request-better-logging-functionality
2023-01-19 09:01:43 -05:00
Lew Rossman
6db17193f5
New positional control valve added
2022-08-16 11:47:44 -04:00
Lew Rossman
6ccddb811d
Update hydstatus.c
2022-08-08 18:37:07 -04:00
Lew Rossman
2d783041a4
Fix for FCV problem
...
This update prevents a solution where the computed loss coefficient for a FCV at its flow setting would be less than the user supplied fully opened coefficient.
2022-08-08 18:08:45 -04:00
Sam Hatchett
9b3007ff55
adds projectless function declarations
...
and fixes non-camelcase convention
2022-08-08 12:02:22 -04:00
Sam Hatchett
b139684164
fixes non-camelcase convention
...
and adds rich corinthian vintage-style (projectless) function declarations
2022-08-08 11:58:09 -04:00
Lew Rossman
79b4fa45a1
Update hydcoeffs.c
...
Only an Active PSV needs to preserve connectivity.
2022-08-05 16:59:32 -04:00
Lew Rossman
93389ad1e4
Fix for PRV directly downstream of a PSV
2022-08-03 19:52:01 -04:00
Sam Hatchett
41887e9016
adds client callback API function
2022-07-27 16:37:49 -04:00
Sam Hatchett
5f8ee49fd6
adds an API function to get information about upcoming events
2022-07-27 14:18:50 -04:00
Sam Hatchett
c500cddd6d
fixes issue where a string position an underflow ( #676 )
...
under some circumstances, like certain input lines that have long comments, the code here can cause an underflow in size_t which casts to a very large integer during comparison and results in the number of tokens being over-reported (max of 40). Most of these tokens are of course garbage. Changing this `len` variable to an integer permits it to be less than zero, thus allowing an exit from the `while` at L665.
2022-06-14 09:36:56 -04:00
Lew Rossman
4d66af19a5
Merge pull request #669 from OpenWaterAnalytics/dev-pump-fix
...
Modify const. HP pump
2022-04-05 09:15:18 -04:00
Luke Butler
9c0b576182
Fix for GPV controls in EN_saveinpfile
...
EN_saveinpfile was incorrectly saving the index of the GPV head loss curve inside of a simple control instead of the control status
2022-03-30 23:13:48 -04:00
Lew Rossman
4bdbe6cd78
Modify const. HP pump
2022-03-30 09:22:01 -04:00
Lew Rossman
cecc941d29
Update to force re-check of PR
2022-03-20 09:27:37 -04:00
Lew Rossman
dbd3f6387d
Fixes possible integer overflow
...
Fixes a possible integer overflow when computing time for a tank to fill/empty (issue #666 ). Also fixes issue #642 that failed to set a pump's initial setting to 0 when its initial status was CLOSED.
2022-03-19 13:25:55 -04:00
Lew Rossman
c8a3eadfdf
Merge pull request #634 from OpenWaterAnalytics/dev-PDA_mod
...
Dev pda mod
2022-03-19 08:53:15 -04:00
Lew Rossman
a63f553b5f
Adds PDA convergence test
2022-02-14 11:19:00 -05:00
Lew Rossman
070901d6bf
Update hydsolver.c
2022-02-14 11:03:22 -05:00
Lew Rossman
f9189d04b4
Updates to default demand pattern fix
2022-01-15 11:21:24 -05:00
Lew Rossman
14de37d0cb
Adjust default pattern index after a pattern is deleted
2022-01-14 09:09:32 -05:00
Lew Rossman
afda609223
Adds get/set for default demand pattern to toolkit
2022-01-14 08:50:33 -05:00
Elad Salomons
64f0d15afe
Merge pull request #657 from OpenWaterAnalytics/dev-Qualflag_Fix
...
Removes silent change to WQ option for 0 duration run
2021-09-28 10:09:26 +03:00
Lew Rossman
d552d0c92c
Removes silent change to WQ option for 0 duration run
2021-09-25 09:32:20 -04:00