## Release Notes for EPANET 2.3
This document describes the changes and updates that have been made in version 2.3 of EPANET.
- The check for at least two nodes, one tank/reservoir and no unconnected junction nodes was moved from `EN_open` to `EN_openH` and `EN_openQ` so that partial network data files could be opened by the toolkit.
- A `EN_setcurvetype` function was added to allow API clients to set a curve's type (e.g., `EN_PUMP_CURVE,` `EN_VOLUME_CURVE,` etc.).
- A `EN_setvertex` function was added to allow API clients to change the coordinates of a single link vertex.
- The index of a General Purpose Valve's (GPV's) head loss curve was added to the list of editable Link Properties using the symbolic constant name `EN_GPV_CURVE`.
- The `EN_getlinkvalue` and `EN_setlinkvalue` functions were updated to get and set the value of `EN_GPV_CURVE`.
- Negative pressure values for `EN_SETTING` are now permitted in the `EN_setlinkvalue` function.
- The `EN_STARTTIME` parameter was added into the `EN_settimeparam` function.
- A `EN_DEMANDPATTERN` parameter was added as the index of the default time pattern used by demands with no specific pattern assigned. It can be set or retrieved with the `EN_setoption` and `EN_getoption` functions, respectively, and is saved to file when the `EN_saveinpfile` function is called.
- The `EN_getaveragepatternvalue` function will now accept a pattern index of 0 which represents the constant pattern assigned to junction demands by default.
- The adjustment of a tank's minimum volume (`Vmin`) when its parameters are changed using `EN_setnodevalue` or `EN_settankdata` has been corrected.
- A pump whose status is set to CLOSED in the input file now also has its speed setting set to 0 which fixes having a simple pressure control activate the pump correctly.
- A failure to raise an error condition for a pipe roughness <= 0 in the input file has been fixed.
- The calculation of head loss gradient for low flow conditions was corrected.
- Improved updating and convergence tests were added to pressure dependent demand analysis.
- Improved checks to prevent outflow from empty tanks or inflow to full (non-overflow) tanks, including the case where a link is connected to a pair of tanks.
- The CI regression test protocol was modified by:
- changing the absolute tolerance used to compare the closeness of test results to benchmark values from 0 to 0.0001
- dropping the "correct decimal digits" test
- dropping the check for identical status report content since it prevents accepting code changes that produce more accurate solutions in fewer iterations.
- A possible loss of network connectivity when evaluating a Pressure Sustaining Valve was prevented.
- Having the implied loss coefficient for an active Flow Control Valve be less than its fully opened value was prevented.
- A new type of valve, a Positional Control Valve (PCV), was added that uses a valve characteristic curve to relate its loss coefficient to its fraction open setting.
- A new set of functions have been added to get information about upcoming time step events. Users will now see what type of event is going to cause the end of a time step to occur. See ENtimetonextevent and EN_timetonextevent.
- A new set of functions have been added to allow users to set a reporting callback function. The user-supplied function will recieve all output normally directed to the report file.
- A `EN_EMITBACKFLOW` option was added that either allows emitters to have reverse flow through them (the default) or not.
- Elevation was not set correctly when using `EN_settankdata` with SI units, this has been fixed.
- The `EN_INITSETTING` option in function `EN_getlinkvalue` will return 0 if the setting equals MISSING due to a fixed `OPEN/CLOSED` status.
- The functions `EN_getnodevalue` and `EN_getlinkvalue` now includes options `EN_NODE_INCONTROL` and `EN_LINK_INCONTROL` to determine whether a node or link participates in a simple or rule-based control.
- Setting a minor loss of zero with `EN_setlinkvalue(ph, index, EN_MINORLOSS, 0)` would raise an error, this has been fixed.
- The reporting of unconnected nodes was not displaying correctly, this has been fixed.
- A header file for C# has been added.
- A new error code `263 - node is not a tank` is returned for when passing a non-tank node index to `EN_settankdata` or `EN_setnodevalue` with option `EN_TANKLEVEL`, `EN_TANKDIAM`, `EN_MINVOLUME`, `EN_VOLCURVE`, `EN_MINLEVEL`, `EN_MAXLEVEL`, `EN_MIXMODEL`, `EN_MIXFRACTION`, `EN_TANK_KBULK` or `EN_CANOVERFLOW`.
- The function `EN_saveinpfile` was incorrectly setting simple controls using GPV with the index of their head loss curve instead of their status, this has been fixed.
- Added support for Conan dependency manager.
- Fix silent Qualflag reset when QUALITY is not NONE and simulation duration is 0 in EPANET input file.
- Added support for cubic meters per second flow units.
- A simple control with more than 9 input tokens would set the incorrect hour, this has been fixed.
- When reading an EPANET inp file, errors in node and link vertex coordinates are ignored.
- Non-zero demands are now not included in `[DEMANDS]` when running `EN_saveinpfile`.
- `EN_SET_CLOSED` and `EN_SET_OPEN` constants were added that can be used with `EN_setcontrol` to fix the status of pipes and valves to completely closed or completely open.