## Release Notes for EPANET 2.3
This document describes the changes and updates that have been made in version 2.3 of EPANET.
- The check for at least two nodes, one tank/reservoir and no unconnected junction nodes was moved from `EN_open` to `EN_openH` and `EN_openQ` so that partial network data files could be opened by the toolkit.
- A `EN_setcurvetype` function was added to allow API clients to set a curve's type (e.g., `EN_PUMP_CURVE,` `EN_VOLUME_CURVE,` etc.).
- A `EN_setvertex` function was added to allow API clients to change the coordinates of a single link vertex.
- The index of a General Purpose Valve's (GPV's) head loss curve was added to the list of editable Link Properties using the symbolic constant name `EN_GPV_CURVE`.
- The `EN_getlinkvalue` and `EN_setlinkvalue` functions were updated to get and set the value of `EN_GPV_CURVE`.
- Negative pressure values for `EN_SETTING` are now permitted in the `EN_setlinkvalue` function.
- The `EN_STARTTIME` parameter was added into the `EN_settimeparam` function.
- A `EN_DEMANDPATTERN` parameter was added as the index of the default time pattern used by demands with no specific pattern assigned. It can be set or retrieved with the `EN_setoption` and `EN_getoption` functions, respectively, and is saved to file when the `EN_saveinpfile` function is called.
- The `EN_getaveragepatternvalue` function will now accept a pattern index of 0 which represents the constant pattern assigned to junction demands by default.
- The adjustment of a tank's minimum volume (`Vmin`) when its parameters are changed using `EN_setnodevalue` or `EN_settankdata` has been corrected.
- A pump whose status is set to CLOSED in the input file now also has its speed setting set to 0 which fixes having a simple pressure control activate the pump correctly.
- A failure to raise an error condition for a pipe roughness <= 0 in the input file has been fixed.
- The calculation of head loss gradient for low flow conditions was corrected.
- Improved updating and convergence tests were added to pressure dependent demand analysis.
- Improved checks to prevent outflow from empty tanks or inflow to full (non-overflow) tanks. *(Still needs more work).*
- The CI regression test protocol was modified by:
- changing the absolute tolerance used to compare the closeness of test results to benchmark values from 0 to 0.0001
- dropping the "correct decimal digits" test
- dropping the check for identical status report content since it prevents accepting code changes that produce more accurate solutions in fewer iterations.
- A possible loss of network connectivity when evaluating a Pressure Sustaining Valve was prevented.
- Having the implied loss coefficient for an active Flow Control Valve be less than its fully opened value was prevented.