Release Notes for EPANET 2.3
This document describes the changes and updates that have been made in version 2.3 of EPANET.
- The check for at least two nodes, one tank/reservoir and no unconnected junction nodes was moved from
EN_opentoEN_openHandEN_openQso that partial network data files can be opened by the toolkit. - A
EN_setcurvetypefunction was added to allow API clients to set a curve's type (e.g.,EN_PUMP_CURVE,EN_VOLUME_CURVE,etc.). - A
EN_setvertexfunction was added to allow API clients to change the coordinates of a link's vertex. - The index of a General Purpose Valve's (GPV's) head loss curve was added to the list of editable Link Properties using the symbolic constant name
EN_GPV_CURVE. - The
EN_getlinkvalueandEN_setlinkvaluefunctions were updated to get and set the value ofEN_GPV_CURVE. - For
EN_CUSTOMtype pump curves the maximum head value is now extrapolated to the y-axis intercept instead of being based on the first curve data point. Similarly, the maximum flow value is extrapolated to the x-axis intercept. - Status checking for a pump not able to deliver enough head has been replaced by adding a penalty term to the pump's operating curve that prevents it from having negative flow (i.e., from crossing the y-axis).
- Status checking for Flow Control Valves has been eliminated by using a continuous head v. flow function. If the current flow is below the valve setting then the normal open head loss relation is used; otherwise a linear penalty function is applied to any flow in excess of the setting. Warnings are no longer issued when the valve operates fully opened at flows below the setting.
- The maximum link head loss error convergence criterion is now evaluated using the most recently computed link flows instead of flows from the previous iteration.