Page 1 Fri Mar 23 14:42:20 2018
******************************************************************
* E P A N E T *
* Hydraulic and Water Quality *
* Analysis for Pipe Networks *
* Version 2.00.12 *
******************************************************************
Analysis begun Fri Mar 23 14:42:20 2018
Hydraulic Status:
-----------------------------------------------------------------------
0:00:00: Balancing the network:
Trial 1: relative flow change = 1.094712
FCV 47 switched from active to open
Trial 2: relative flow change = 1.078480
Pump 29 switched from open to closed
Trial 3: relative flow change = 0.279262
Pump 29 switched from closed to open
Trial 4: relative flow change = 0.264348
Trial 5: relative flow change = 0.000008
0:00:00: Balanced after 5 trials
0:00:00: Reservoir 1 is emptying
0:00:00: Reservoir 32 is emptying
0:00:00: FCV 47 open but cannot deliver flow
WARNING: Negative pressures at 0:00:00 hrs.
WARNING: FCV 47 open but cannot deliver flow at 0:00:00 hrs.
Analysis ended Fri Mar 23 14:42:20 2018