import json
from datetime import datetime
from math import pi, sqrt
import pytz
import app.services.simulation as simulation
from app.algorithms.api_ex.run_simulation import (
run_simulation_ex,
from_clock_to_seconds_2,
)
from app.native.api.project import copy_project
from app.services.epanet.epanet import Output
from app.services.scheme_management import store_scheme_info
from app.services.tjnetwork import *
############################################################
# burst analysis 01
############################################################
def convert_to_local_unit(proj: str, emitters: float) -> float:
open_project(proj)
proj_opt = get_option(proj)
str_unit = proj_opt.get("UNITS")
if str_unit == "CMH":
return emitters * 3.6
elif str_unit == "LPS":
return emitters
elif str_unit == "CMS":
return emitters / 1000.0
elif str_unit == "MGD":
return emitters * 0.0438126
# Unknown unit: log and return original value
print(str_unit)
return emitters
def burst_analysis(
name: str,
modify_pattern_start_time: str,
burst_ID: list | str = None,
burst_size: list | float | int = None,
modify_total_duration: int = 900,
modify_fixed_pump_pattern: dict[str, list] = None,
modify_variable_pump_pattern: dict[str, list] = None,
modify_valve_opening: dict[str, float] = None,
scheme_name: str = None,
) -> None:
"""
爆管模拟
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param burst_ID: 爆管管道的ID选取的是管道单独传入一个爆管管道可以是str或list传入多个爆管管道是用list
:param burst_size: 爆管管道破裂的孔口面积和burst_ID列表各位置的ID对应以cm*cm计算
:param modify_total_duration: 模拟总历时,秒
:param modify_fixed_pump_pattern: dict中包含多个水泵模式str为工频水泵的idlist为修改后的pattern
:param modify_variable_pump_pattern: dict中包含多个水泵模式str为变频水泵的idlist为修改后的pattern
:param modify_valve_opening: dict中包含多个阀门开启度str为阀门的idfloat为修改后的阀门开启度
:param scheme_name: 方案名称
:return:
"""
scheme_detail: dict = {
"burst_ID": burst_ID,
"burst_size": burst_size,
"modify_total_duration": modify_total_duration,
"modify_fixed_pump_pattern": modify_fixed_pump_pattern,
"modify_variable_pump_pattern": modify_variable_pump_pattern,
"modify_valve_opening": modify_valve_opening,
}
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"burst_Anal_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
simulation.run_simulation(
name=new_name,
simulation_type="manually_temporary",
modify_pattern_start_time=modify_pattern_start_time,
)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
##step 1 set the emitter coefficient of end node of busrt pipe
if isinstance(burst_ID, list):
if (burst_size is not None) and (type(burst_size) is not list):
return json.dumps("Type mismatch.")
elif isinstance(burst_ID, str):
burst_ID = [burst_ID]
if burst_size is not None:
if isinstance(burst_size, float) or isinstance(burst_size, int):
burst_size = [burst_size]
else:
return json.dumps("Type mismatch.")
else:
return json.dumps("Type mismatch.")
if burst_size is None:
burst_size = [-1] * len(burst_ID)
elif len(burst_size) < len(burst_ID):
burst_size += [-1] * (len(burst_ID) - len(burst_size))
elif len(burst_size) > len(burst_ID):
# burst_size = burst_size[:len(burst_ID)]
return json.dumps("Length mismatch.")
for burst_ID_, burst_size_ in zip(burst_ID, burst_size):
pipe = get_pipe(new_name, burst_ID_)
str_start_node = pipe["node1"]
str_end_node = pipe["node2"]
d_pipe = pipe["diameter"] / 1000.0
if burst_size_ <= 0:
burst_size_ = 3.14 * d_pipe * d_pipe / 4 / 8
else:
burst_size_ = burst_size_ / 10000
emitter_coeff = (
0.65 * burst_size_ * sqrt(19.6) * 1000
) # 1/8开口面积作为coeff单位 L/S
emitter_coeff = convert_to_local_unit(new_name, emitter_coeff)
emitter_node = ""
if is_junction(new_name, str_end_node):
emitter_node = str_end_node
elif is_junction(new_name, str_start_node):
emitter_node = str_start_node
old_emitter = get_emitter(new_name, emitter_node)
if old_emitter != None:
old_emitter["coefficient"] = emitter_coeff # 爆管的emitter coefficient设置
else:
old_emitter = {"junction": emitter_node, "coefficient": emitter_coeff}
new_emitter = ChangeSet()
new_emitter.append(old_emitter)
set_emitter(new_name, new_emitter)
# step 2. run simulation
# 涉及关阀计算可能导致关阀后仍有流量改为压力驱动PDA
options = get_option(new_name)
options["DEMAND MODEL"] = OPTION_DEMAND_MODEL_PDA
options["REQUIRED PRESSURE"] = "10.0000"
cs_options = ChangeSet()
cs_options.append(options)
set_option(new_name, cs_options)
# valve_control = None
# if modify_valve_opening is not None:
# valve_control = {}
# for valve in modify_valve_opening:
# valve_control[valve] = {'status': 'CLOSED'}
# result = run_simulation_ex(new_name,'realtime', modify_pattern_start_time,
# end_datetime=modify_pattern_start_time,
# modify_total_duration=modify_total_duration,
# modify_pump_pattern=modify_pump_pattern,
# valve_control=valve_control,
# downloading_prohibition=True)
simulation.run_simulation(
name=new_name,
simulation_type="extended",
modify_pattern_start_time=modify_pattern_start_time,
modify_total_duration=modify_total_duration,
modify_fixed_pump_pattern=modify_fixed_pump_pattern,
modify_variable_pump_pattern=modify_variable_pump_pattern,
modify_valve_opening=modify_valve_opening,
scheme_type="burst_analysis",
scheme_name=scheme_name,
)
# step 3. restore the base model status
# execute_undo(name) #有疑惑
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# 存储方案信息到 PG 数据库
store_scheme_info(
name=name,
scheme_name=scheme_name,
scheme_type="burst_analysis",
username="admin",
scheme_start_time=modify_pattern_start_time,
scheme_detail=scheme_detail,
)
############################################################
# valve closing analysis 02
############################################################
def valve_close_analysis(
name: str,
modify_pattern_start_time: str,
modify_total_duration: int = 900,
modify_valve_opening: dict[str, float] = None,
scheme_name: str = None,
) -> None:
"""
关阀模拟
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param modify_total_duration: 模拟总历时,秒
:param modify_valve_opening: dict中包含多个阀门开启度str为阀门的idfloat为修改后的阀门开启度
:param scheme_name: 方案名称
:return:
"""
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"valve_close_Anal_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
# step 1. change the valves status to 'closed'
# for valve in valves:
# if not is_valve(new_name,valve):
# result='ID:{}is not a valve type'.format(valve)
# return result
# cs=ChangeSet()
# status=get_status(new_name,valve)
# status['status']='CLOSED'
# cs.append(status)
# set_status(new_name,cs)
# step 2. run simulation
# 涉及关阀计算可能导致关阀后仍有流量改为压力驱动PDA
options = get_option(new_name)
options["DEMAND MODEL"] = OPTION_DEMAND_MODEL_PDA
options["REQUIRED PRESSURE"] = "20.0000"
cs_options = ChangeSet()
cs_options.append(options)
set_option(new_name, cs_options)
# result = run_simulation_ex(new_name,'realtime', modify_pattern_start_time, modify_pattern_start_time, modify_total_duration,
# downloading_prohibition=True)
simulation.run_simulation(
name=new_name,
simulation_type="extended",
modify_pattern_start_time=modify_pattern_start_time,
modify_total_duration=modify_total_duration,
modify_valve_opening=modify_valve_opening,
scheme_Type="valve_close_Analysis",
scheme_name=scheme_name,
)
# step 3. restore the base model
# for valve in valves:
# execute_undo(name)
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# return result
############################################################
# flushing analysis 03
# Pipe_Flushing_Analysis(prj_name,date_time, Valve_id_list, Drainage_Node_Id, Flushing_flow[opt], Flushing_duration[opt])->out_file:string
############################################################
def flushing_analysis(
name: str,
modify_pattern_start_time: str,
modify_total_duration: int = 900,
modify_valve_opening: dict[str, float] = None,
drainage_node_ID: str = None,
flushing_flow: float = 0,
scheme_name: str = None,
) -> None:
"""
管道冲洗模拟
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param modify_total_duration: 模拟总历时,秒
:param modify_valve_opening: dict中包含多个阀门开启度str为阀门的idfloat为修改后的阀门开启度
:param drainage_node_ID: 冲洗排放口所在节点ID
:param flushing_flow: 冲洗水量传入参数单位为m3/h
:param scheme_name: 方案名称
:return:
"""
scheme_detail: dict = {
"duration": modify_total_duration,
"valve_opening": modify_valve_opening,
"drainage_node_ID": drainage_node_ID,
"flushing_flow": flushing_flow,
}
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"flushing_Anal_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# if is_project_open(name):
# close_project(name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
if not is_junction(new_name, drainage_node_ID):
return "Wrong Drainage node type"
# step 1. change the valves status to 'closed'
# for valve, valve_k in zip(valves, valves_k):
# cs=ChangeSet()
# status=get_status(new_name,valve)
# # status['status']='CLOSED'
# if valve_k == 0:
# status['status'] = 'CLOSED'
# elif valve_k < 1:
# status['status'] = 'OPEN'
# status['setting'] = 0.1036 * pow(valve_k, -3.105)
# cs.append(status)
# set_status(new_name,cs)
units = get_option(new_name)
# step 2. set the emitter coefficient of drainage node or add flush flow to the drainage node
emitter_demand = get_demand(new_name, drainage_node_ID)
cs = ChangeSet()
if flushing_flow > 0:
for r in emitter_demand["demands"]:
if units == "LPS":
r["demand"] += flushing_flow / 3.6
elif units == "CMH":
r["demand"] += flushing_flow
cs.append(emitter_demand)
set_demand(new_name, cs)
else:
pipes = get_node_links(new_name, drainage_node_ID)
flush_diameter = 50
for pipe in pipes:
d = get_pipe(new_name, pipe)["diameter"]
if flush_diameter < d:
flush_diameter = d
flush_diameter /= 1000
emitter_coeff = (
0.65 * 3.14 * (flush_diameter * flush_diameter / 4) * sqrt(19.6) * 1000
) # 全开口面积作为coeff
old_emitter = get_emitter(new_name, drainage_node_ID)
if old_emitter != None:
old_emitter["coefficient"] = emitter_coeff # 爆管的emitter coefficient设置
else:
old_emitter = {"junction": drainage_node_ID, "coefficient": emitter_coeff}
new_emitter = ChangeSet()
new_emitter.append(old_emitter)
set_emitter(new_name, new_emitter)
# step 3. run simulation
# 涉及关阀计算可能导致关阀后仍有流量改为压力驱动PDA
options = get_option(new_name)
options["DEMAND MODEL"] = OPTION_DEMAND_MODEL_PDA
options["REQUIRED PRESSURE"] = "20.0000"
cs_options = ChangeSet()
cs_options.append(options)
set_option(new_name, cs_options)
# result = run_simulation_ex(new_name,'realtime', modify_pattern_start_time, modify_pattern_start_time, modify_total_duration,
# downloading_prohibition=True)
simulation.run_simulation(
name=new_name,
simulation_type="extended",
modify_pattern_start_time=modify_pattern_start_time,
modify_total_duration=modify_total_duration,
modify_valve_opening=modify_valve_opening,
scheme_Type="flushing_Analysis",
scheme_name=scheme_name,
)
# step 4. restore the base model
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# return result
# 存储方案信息到 PG 数据库
store_scheme_info(
name=name,
scheme_name=scheme_name,
scheme_type="flushing_analysis",
username="admin",
scheme_start_time=modify_pattern_start_time,
scheme_detail=scheme_detail,
)
############################################################
# Contaminant simulation 04
#
############################################################
def contaminant_simulation(
name: str,
modify_pattern_start_time: str, # 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
modify_total_duration: int, # 模拟总历时,秒
source: str, # 污染源节点ID
concentration: float, # 污染源浓度单位mg/L
scheme_name: str = None,
source_pattern: str = None, # 污染源时间变化模式名称
) -> None:
"""
污染模拟
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param modify_total_duration: 模拟总历时,秒
:param source: 污染源所在的节点ID
:param concentration: 污染源位置处的浓度单位mg/L。默认的污染模拟setting为SOURCE_TYPE_CONCEN改为SOURCE_TYPE_SETPOINT
:param source_pattern: 污染源的时间变化模式若不传入则默认以恒定浓度持续模拟时间长度等于duration;
若传入,则格式为{1.0,0.5,1.1}等系数列表pattern_step模拟等于模型的hydraulic time step
:param scheme_name: 方案名称
:return:
"""
scheme_detail: dict = {
"source": source,
"concentration": concentration,
"duration": modify_total_duration,
"pattern": source_pattern,
}
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"contaminant_Sim_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# if is_project_open(name):
# close_project(name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
dic_time = get_time(new_name)
dic_time["QUALITY TIMESTEP"] = "0:05:00"
cs = ChangeSet()
cs.operations.append(dic_time)
set_time(new_name, cs) # set QUALITY TIMESTEP
time_option = get_time(new_name)
hydraulic_step = time_option["HYDRAULIC TIMESTEP"]
secs = from_clock_to_seconds_2(hydraulic_step)
operation_step = 0
# step 1. set duration
if modify_total_duration == None:
modify_total_duration = secs
# step 2. set pattern
if source_pattern != None:
pt = get_pattern(new_name, source_pattern)
if pt == None:
str_response = str("cant find source_pattern")
return str_response
else:
cs_pattern = ChangeSet()
pt = {}
factors = []
tmp_duration = modify_total_duration
while tmp_duration > 0:
factors.append(1.0)
tmp_duration = tmp_duration - secs
pt["id"] = "contam_pt"
pt["factors"] = factors
cs_pattern.append(pt)
add_pattern(new_name, cs_pattern)
operation_step += 1
# step 3. set source/initial quality
# source quality
cs_source = ChangeSet()
source_schema = {
"node": source,
"s_type": SOURCE_TYPE_SETPOINT,
"strength": concentration,
"pattern": pt["id"],
}
cs_source.append(source_schema)
source_node = get_source(new_name, source)
if len(source_node) == 0:
add_source(new_name, cs_source)
else:
set_source(new_name, cs_source)
dict_demand = get_demand(new_name, source)
for demands in dict_demand["demands"]:
dict_demand["demands"][dict_demand["demands"].index(demands)]["demand"] = -1
dict_demand["demands"][dict_demand["demands"].index(demands)]["pattern"] = None
cs = ChangeSet()
cs.append(dict_demand)
set_demand(new_name, cs) # set inflow node
# # initial quality
# dict_quality = get_quality(new_name, source)
# dict_quality['quality'] = concentration
# cs = ChangeSet()
# cs.append(dict_quality)
# set_quality(new_name, cs)
operation_step += 1
# step 4 set option of quality to chemical
opt = get_option(new_name)
opt["QUALITY"] = OPTION_QUALITY_CHEMICAL
cs_option = ChangeSet()
cs_option.append(opt)
set_option(new_name, cs_option)
operation_step += 1
# step 5. run simulation
# result = run_simulation_ex(new_name,'realtime', modify_pattern_start_time, modify_pattern_start_time, modify_total_duration,
# downloading_prohibition=True)
simulation.run_simulation(
name=new_name,
simulation_type="extended",
modify_pattern_start_time=modify_pattern_start_time,
modify_total_duration=modify_total_duration,
scheme_type="contaminant_analysis",
scheme_name=scheme_name,
)
# for i in range(1,operation_step):
# execute_undo(name)
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# 存储方案信息到 PG 数据库
store_scheme_info(
name=name,
scheme_name=scheme_name,
scheme_type="contaminant_analysis",
username="admin",
scheme_start_time=modify_pattern_start_time,
scheme_detail=scheme_detail,
)
############################################################
# age analysis 05 ***水龄模拟目前还没和实时模拟打通,不确定是否需要,先不要使用***
############################################################
def age_analysis(
name: str, modify_pattern_start_time: str, modify_total_duration: int = 900
) -> None:
"""
水龄模拟
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param modify_total_duration: 模拟总历时,秒
:return:
"""
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"age_Anal_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# if is_project_open(name):
# close_project(name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
# step 1. run simulation
result = run_simulation_ex(
new_name,
"realtime",
modify_pattern_start_time,
modify_total_duration,
downloading_prohibition=True,
)
# step 2. restore the base model status
# execute_undo(name) #有疑惑
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
output = Output("./temp/{}.db.out".format(new_name))
# element_name = output.element_name()
# node_name = element_name['nodes']
# link_name = element_name['links']
nodes_age = []
node_result = output.node_results()
for node in node_result:
nodes_age.append(node["result"][-1]["quality"])
links_age = []
link_result = output.link_results()
for link in link_result:
links_age.append(link["result"][-1]["quality"])
age_result = {"nodes": nodes_age, "links": links_age}
# age_result = {'nodes': nodes_age, 'links': links_age, 'nodeIDs': node_name, 'linkIDs': link_name}
return json.dumps(age_result)
############################################################
# pressure regulation 06
############################################################
def pressure_regulation(
name: str,
modify_pattern_start_time: str,
modify_total_duration: int = 900,
modify_tank_initial_level: dict[str, float] = None,
modify_fixed_pump_pattern: dict[str, list] = None,
modify_variable_pump_pattern: dict[str, list] = None,
scheme_name: str = None,
) -> None:
"""
区域调压模拟用来模拟未来15分钟内开关水泵对区域压力的影响
:param name: 模型名称,数据库中对应的名字
:param modify_pattern_start_time: 模拟开始时间,格式为'2024-11-25T09:00:00+08:00'
:param modify_total_duration: 模拟总历时,秒
:param modify_tank_initial_level: dict中包含多个水塔str为水塔的idfloat为修改后的initial_level
:param modify_fixed_pump_pattern: dict中包含多个水泵模式str为工频水泵的idlist为修改后的pattern
:param modify_variable_pump_pattern: dict中包含多个水泵模式str为变频水泵的idlist为修改后的pattern
:param scheme_name: 模拟方案名称
:return:
"""
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Analysis."
)
new_name = f"pressure_regulation_{name}"
if have_project(new_name):
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# if is_project_open(name):
# close_project(name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Copying Database."
)
# CopyProjectEx()(name, new_name,
# ['operation', 'current_operation', 'restore_operation', 'batch_operation', 'operation_table'])
copy_project(name + "_template", new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Start Opening Database."
)
open_project(new_name)
print(
datetime.now(pytz.timezone("Asia/Shanghai")).strftime("%Y-%m-%d %H:%M:%S")
+ " -- Database Loading OK."
)
# 全部关泵后压力计算不合理改为压力驱动PDA
options = get_option(new_name)
options["DEMAND MODEL"] = OPTION_DEMAND_MODEL_PDA
options["REQUIRED PRESSURE"] = "15.0000"
cs_options = ChangeSet()
cs_options.append(options)
set_option(new_name, cs_options)
# result = run_simulation_ex(name=new_name,
# simulation_type='realtime',
# start_datetime=start_datetime,
# duration=900,
# pump_control=pump_control,
# tank_initial_level_control=tank_initial_level_control,
# downloading_prohibition=True)
simulation.run_simulation(
name=new_name,
simulation_type="extended",
modify_pattern_start_time=modify_pattern_start_time,
modify_total_duration=modify_total_duration,
modify_tank_initial_level=modify_tank_initial_level,
modify_fixed_pump_pattern=modify_fixed_pump_pattern,
modify_variable_pump_pattern=modify_variable_pump_pattern,
scheme_Type="pressure_regulation",
scheme_name=scheme_name,
)
if is_project_open(new_name):
close_project(new_name)
delete_project(new_name)
# return result