Files
TJWaterServerBinary/app/services/dma_leakage_estimation.py
T
jiang 5966d039de refactor(backend)!: separate algorithm and data layers
Reorganize algorithm packages by business responsibility, move orchestration into services, and keep database access behind pooled repositories.

Harden analysis API validation, remove unsafe legacy simulation endpoints, and add regression and architecture boundary coverage.

BREAKING CHANGE: legacy algorithm module paths and obsolete simulation endpoints are removed.
2026-09-04 17:30:55 +08:00

342 lines
12 KiB
Python

import os
from datetime import datetime
from typing import Any
import pandas as pd
from app.algorithms.dma_leakage_estimation.genetic_optimizer import DmaLeakageOptimizer
from app.algorithms.dma_leakage_estimation.topology_partitioning import (
build_dma_partitions,
)
from app.infra.db.timescaledb.internal_queries import InternalQueries
from app.infra.db.postgresql.scada import get_all_scada_info
from app.native.wndb.gis.network_views import (
get_network_link_nodes,
get_network_node_coords,
)
from app.native.wndb.inp.exporter import dump_inp
from app.services.scheme_management import store_analysis_run_with_result
from app.domain.time import parse_utc_time, utc_now
DEFAULT_N_WORKERS = max(1, min((os.cpu_count() or 1) - 1, 4))
def run_leakage_identification(
network: str,
username: str,
observed_pressure_data: (
pd.DataFrame | dict[str, list[Any]] | list[dict[str, Any]] | None
) = None,
start_time: float = 0,
duration: float = 24,
timestep: float = 5,
q_sum: float = 0.2,
q_sum_unit: str = "m3/s",
pop_size: int = 50,
max_gen: int = 100,
n_workers: int = DEFAULT_N_WORKERS,
output_flow_unit: str = "m3/s",
dma_count: int | None = None,
scada_start: datetime | str | None = None,
scada_end: datetime | str | None = None,
sensor_nodes: list[str] | None = None,
scheme_name: str | None = None,
) -> dict[str, Any]:
inp_path = _prepare_leakage_inp(network)
selected_sensor_nodes = (
list(dict.fromkeys([node for node in (sensor_nodes or []) if node]))
if sensor_nodes
else _get_pressure_sensor_nodes(network)
)
if not selected_sensor_nodes:
raise ValueError("未提供有效传感器节点,且系统未识别到可用压力传感器。")
area_map, areas, node_coords = _build_area_map_by_topology(
network, selected_sensor_nodes, dma_count
)
observed_source = "request_payload"
if scada_start is not None or scada_end is not None:
observed_df = _build_observed_pressure_from_scada(
network=network,
sensor_nodes=selected_sensor_nodes,
scada_start=scada_start,
scada_end=scada_end,
)
observed_source = "backend_timerange"
else:
if observed_pressure_data is None:
raise ValueError(
"未提供 observed_pressure_data,且未提供 scada_start/scada_end。"
)
observed_df = observed_pressure_data
q_sum_m3s = DmaLeakageOptimizer._flow_to_m3s(q_sum, q_sum_unit)
identifier = DmaLeakageOptimizer(
inp_path=inp_path,
sensor_nodes=selected_sensor_nodes,
area_map=area_map,
start_time=start_time,
duration=duration,
timestep=timestep,
q_sum=q_sum_m3s,
)
result_df = identifier.run_identification(
observed_pressure_data=observed_df,
pop_size=pop_size,
max_gen=max_gen,
n_workers=n_workers,
output_flow_unit=output_flow_unit,
save_result=False,
)
rows = result_df.to_dict(orient="records")
# node_visual_payload = _build_node_visual_payload(area_map, node_coords, rows)
# drawing_payload = _build_drawing_payload(node_visual_payload)
payload = {
"result_path": result_df.attrs.get("result_path"),
"sensor_nodes": selected_sensor_nodes,
"observed_source": observed_source,
"area_count": len(set(area_map.values())),
"node_area_map": area_map,
"areas": areas,
# "node_visual_payload": node_visual_payload,
# "drawing_payload": drawing_payload,
"rows": rows,
}
if scheme_name:
scheme_start_time = (
_to_datetime(scada_start).isoformat()
if scada_start is not None
else utc_now().isoformat()
)
scheme_detail = {
"network": network,
"dma_count": dma_count,
"sensor_nodes": selected_sensor_nodes,
"scada_start": (
_to_datetime(scada_start).isoformat()
if scada_start is not None
else None
),
"scada_end": (
_to_datetime(scada_end).isoformat() if scada_end is not None else None
),
"algorithm_params": {
"start_time": start_time,
"duration": duration,
"timestep": timestep,
"q_sum": q_sum,
"q_sum_unit": q_sum_unit,
"output_flow_unit": output_flow_unit,
"pop_size": pop_size,
"max_gen": max_gen,
"n_workers": n_workers,
},
"result_summary": {
"area_count": len(set(area_map.values())),
"max_leakage": max(
(float(row.get("LeakageFlow_m3_per_s", 0.0)) for row in rows),
default=0.0,
),
},
}
store_analysis_run_with_result(
name=network,
scheme_name=scheme_name,
scheme_type="dma_leak_identification",
username=username,
scheme_start_time=scheme_start_time,
scheme_detail=scheme_detail,
result_type="leakage_identification",
result_payload={
"network": network,
"run_status": "completed",
"error_message": None,
"sensor_nodes": selected_sensor_nodes,
"rows": rows,
"node_area_map": area_map,
"areas": areas,
"drawing_payload": {},
},
)
payload["scheme_name"] = scheme_name
return payload
def _get_pressure_sensor_nodes(network: str) -> list[str]:
scada_devices = get_all_scada_info(network)
sensor_nodes: list[str] = []
for item in scada_devices:
scada_type = str(item.get("device_type", "")).lower()
if scada_type != "pressure":
continue
node_id = item.get("node_id")
if isinstance(node_id, str) and node_id:
sensor_nodes.append(node_id)
sensor_nodes = list(dict.fromkeys(sensor_nodes))
if not sensor_nodes:
raise ValueError("未找到关联节点的压力 SCADA 设备。")
return sensor_nodes
def _build_area_map_by_topology(
network: str, sensor_nodes: list[str], dma_count: int | None
) -> tuple[dict[str, str], list[dict[str, Any]], dict[str, dict[str, float]]]:
node_coords = get_network_node_coords(network)
area_map, areas = build_dma_partitions(
sensor_nodes,
node_coords,
get_network_link_nodes(network),
dma_count,
)
return area_map, areas, node_coords
def _build_area_node_map(area_map: dict[str, str]) -> dict[str, list[str]]:
area_node_map: dict[str, list[str]] = {}
for node_id, area_id in area_map.items():
area_node_map.setdefault(area_id, []).append(node_id)
for area_id in list(area_node_map.keys()):
area_node_map[area_id] = sorted(area_node_map[area_id])
return area_node_map
def _build_node_visual_payload(
area_map: dict[str, str],
node_coords: dict[str, dict[str, float]],
rows: list[dict[str, Any]],
) -> dict[str, Any]:
area_leakage_map = _build_area_leakage_map(rows)
max_leakage = max(area_leakage_map.values(), default=0.0)
features: list[dict[str, Any]] = []
for node_id, area_id in area_map.items():
coord = node_coords.get(node_id)
if not coord:
continue
leakage_flow = float(area_leakage_map.get(area_id, 0.0))
leakage_level = _classify_leakage_level(leakage_flow, max_leakage)
features.append(
{
"type": "Feature",
"properties": {
"node_id": node_id,
"area_id": area_id,
"leakage_flow_m3_per_s": leakage_flow,
"leakage_level": leakage_level,
},
"geometry": {
"type": "Point",
"coordinates": [float(coord["x"]), float(coord["y"])],
},
}
)
return {"type": "FeatureCollection", "features": features}
def _build_area_leakage_map(rows: list[dict[str, Any]]) -> dict[str, float]:
area_leakage_map: dict[str, float] = {}
for row in rows:
area_id = str(row.get("Area", "")).strip()
if not area_id:
continue
area_leakage_map[area_id] = float(row.get("LeakageFlow_m3_per_s", 0.0))
return area_leakage_map
def _classify_leakage_level(leakage_flow: float, max_leakage: float) -> str:
if max_leakage <= 0:
return "normal"
ratio = leakage_flow / max_leakage
if ratio >= 0.75:
return "high"
if ratio >= 0.4:
return "medium"
if ratio > 0:
return "low"
return "normal"
def _build_drawing_payload(node_visual_payload: dict[str, Any]) -> dict[str, Any]:
return node_visual_payload
def _build_observed_pressure_from_scada(
network: str,
sensor_nodes: list[str],
scada_start: datetime | str | None,
scada_end: datetime | str | None,
) -> pd.DataFrame:
if scada_start is None or scada_end is None:
raise ValueError("使用后端 SCADA 查询时必须同时提供 scada_start 与 scada_end。")
start_dt = _to_datetime(scada_start)
end_dt = _to_datetime(scada_end)
if start_dt >= end_dt:
raise ValueError("SCADA 时间窗非法:scada_start 必须早于 scada_end。")
node_query_id: dict[str, str] = {}
for item in get_all_scada_info(network):
if str(item.get("device_type", "")).lower() != "pressure":
continue
node_id = item.get("node_id")
query_id = item.get("api_query_id")
if (
isinstance(node_id, str)
and node_id
and isinstance(query_id, str)
and query_id
):
node_query_id[node_id] = query_id
query_ids = [node_query_id[node] for node in sensor_nodes if node in node_query_id]
if not query_ids:
raise ValueError("未找到可用于压力观测的 SCADA api_query_id。")
scada_data = InternalQueries.query_scada_by_ids_timerange(
db_name=network,
device_ids=query_ids,
start_time=start_dt.isoformat(),
end_time=end_dt.isoformat(),
)
available_lengths = [
len(scada_data.get(query_id, []))
for query_id in query_ids
if len(scada_data.get(query_id, [])) > 0
]
if not available_lengths:
raise ValueError("指定时间窗内未查询到压力 SCADA 数据。")
min_len = min(available_lengths)
obs_df = pd.DataFrame()
for node_id in sensor_nodes:
query_id = node_query_id.get(node_id)
if not query_id:
continue
records = scada_data.get(query_id, [])[:min_len]
if len(records) < min_len:
continue
obs_df[node_id] = [float(item["value"]) for item in records]
if obs_df.empty:
raise ValueError("SCADA 压力数据无法构建观测矩阵。")
return obs_df
def _to_datetime(value: datetime | str) -> datetime:
return parse_utc_time(value)
def _prepare_leakage_inp(network: str) -> str:
project_root = os.path.abspath(os.path.join(os.path.dirname(__file__), "..", ".."))
db_inp_dir = os.path.join(project_root, "db_inp")
os.makedirs(db_inp_dir, exist_ok=True)
inp_path = os.path.join(db_inp_dir, f"{network}.leakage.inp")
if os.path.isfile(inp_path) and os.path.getsize(inp_path) > 0:
return inp_path
dump_inp(network, inp_path, "2")
if not os.path.isfile(inp_path) or os.path.getsize(inp_path) <= 0:
raise ValueError(f"漏损识别 INP 文件无效: {inp_path}")
return inp_path