Files
next-tjwater-server/scripts/calibrate_burst_benchmark.py
T

162 lines
10 KiB
Python

#!/usr/bin/env python3
"""Calibrate a read-only model export using file-isolated native EPANET runs."""
from __future__ import annotations
import argparse
import asyncio
import os
import sys
import traceback
from datetime import datetime, timedelta, timezone
from pathlib import Path
from uuid import uuid4
def main() -> int:
parser = argparse.ArgumentParser(description=__doc__)
parser.add_argument("--design", type=Path, default=Path("resources/benchmarks/tjwater2-v2-burst-simulation.json"))
parser.add_argument("--output-root", type=Path, default=Path("data/benchmark-calibration"))
parser.add_argument("--duration-seconds", type=int, help="Override calibration duration, e.g. 18000 for five hours")
parser.add_argument("--timeout-seconds", type=int, default=240)
parser.add_argument("--all-severities", action="store_true", help="Retain weak-signal sizes even if the severe level fails")
args = parser.parse_args()
sys.path.insert(0, str(Path(__file__).resolve().parents[1]))
os.umask(0o077)
report = None
report_path = None
try:
from psycopg.conninfo import make_conninfo
from app.infra.db.project_routing import ActiveProjectRouting, activate_project_routing
from app.native.wndb.core.connection import close_all_project_pools, project_transaction
from app.native.wndb.inp.exporter import dump_inp
from scripts.check_burst_simulation_design import readonly, resolve_project, validate_database, validate_tool_inputs
from scripts.benchmark.simulation_design import load_simulation_design
from scripts.benchmark.calibration import assess, configure_inp, digest, pressure_preview, run_file, save_json, select_calibrated_area
design = load_simulation_design(args.design)
validate_tool_inputs(design)
duration = args.duration_seconds if args.duration_seconds is not None else design.duration_seconds
step = design.model_expectations.report_timestep_seconds
if not 3600 <= duration <= 18000 or duration % step or not 1 <= args.timeout_seconds <= 1800:
raise ValueError("duration must be whole report steps between one and five hours; timeout 1..1800")
biz, _ = asyncio.run(resolve_project(design))
with readonly(biz) as connection:
validate_database(connection, design, template=False)
folder = (args.output_root / (datetime.now(timezone.utc).strftime("%Y%m%dT%H%M%SZ") + "-" + uuid4().hex[:8])).resolve()
folder.mkdir(parents=True, mode=0o700)
snapshot = folder / "source.inp"
readonly_dsn = make_conninfo(biz, options="-c default_transaction_read_only=on -c statement_timeout=20000")
routing = ActiveProjectRouting(project_code=design.project_code, business_dsn=readonly_dsn)
try:
with activate_project_routing(routing), project_transaction(design.project_code) as connection:
connection.execute("SET TRANSACTION ISOLATION LEVEL REPEATABLE READ, READ ONLY")
# Stateless models permit event-aligned runs and independent warmup history.
counts = connection.execute("SELECT (SELECT count(*) FROM network.tanks) tanks, "
"(SELECT count(*) FROM network.pumps) pumps, "
"(SELECT count(*) FROM network.controls) controls, "
"(SELECT count(*) FROM network.rules) rules").fetchone()
if any(counts.values()):
raise ValueError("stateful model requires an explicit warm-start implementation")
pda_options = {row["key"]: row["value"] for row in connection.execute(
"SELECT key,value FROM network.simulation_settings WHERE engine_version='legacy' "
"AND key=ANY(%s)",
(["HEADERROR", "FLOWCHANGE", "MINIMUM PRESSURE", "PRESSURE EXPONENT"],),
)}
dump_inp(design.project_code, str(snapshot), "2")
finally:
close_all_project_pools()
source = snapshot.read_text(encoding="utf-8")
node_ids = sorted({node for pipe in design.pipes for node in pipe.output_node_ids})
link_ids = sorted({link for pipe in design.pipes for link in pipe.output_link_ids})
report = {"version": "burst-calibration@1", "status": "running", "created_at": datetime.now(timezone.utc),
"source_effect": "read-only model export; local file simulations only",
"model_sha256": digest(snapshot), "design_sha256": digest(args.design),
"design": design.model_dump(mode="json"), "duration_seconds": duration,
"pda_options": pda_options,
"assessment_scope": "strong-signal calibration, not Agent accuracy or absence of a physical burst",
"all_severities": args.all_severities,
"engine_sha256": digest(Path("app/infra/epanet/linux/runepanet")),
"cases": [], "selection": {}, "controls": {},
"limitations": ["No analysis scenario or SCADA rows have been persisted",
"No worker, MCP, Agent, or 15-day detection has been executed",
"The four-sample pressure replay rule is a calibration preview"]}
report_path = folder / "calibration.json"
save_json(report_path, report)
def simulate(label, start, seconds, emitter=None):
path = folder / f"{label}.inp"
path.write_text(configure_inp(source, start, seconds, emitter=emitter, pda_options=pda_options), encoding="utf-8")
result = run_file(path, node_ids, link_ids, timeout=args.timeout_seconds)
save_json(folder / f"{label}.json", result)
print(f"{label}: {result['status']}, solver warnings={len(result['warnings'])}", flush=True)
return result
controls = {}
histories = {}
for index, at in enumerate(design.event_times):
controls[at] = simulate(f"normal-{index}", at, duration)
warmup = simulate(f"warmup-{index}", at - timedelta(seconds=4 * step), 3 * step)
if warmup.get("status") != "completed" or warmup.get("warnings") or warmup.get("times") != {
"report_start": 0, "report_step": step, "sim_duration": 3 * step, "num_periods": 4
}:
raise ValueError("normal warmup did not produce four converged samples")
histories[at] = warmup["nodes"]
report["controls"][at.isoformat()] = {"normal_file": f"normal-{index}.json", "warmup_file": f"warmup-{index}.json"}
save_json(report_path, report)
for pipe in design.pipes:
cases = [case for case in design.cases if case.pipe_id == pipe.pipe_id]
passed_levels = []
for severity in design.calibration_order:
level_passed = True
for case in cases:
area = pipe.candidate_orifice_areas_cm2[severity]
burst = simulate(f"{case.case_id}-{severity}", case.occurred_at, duration, (pipe.emitter_node_id, area))
normal = controls[case.occurred_at]
result = assess(pipe, normal, burst, design.selection_rule, duration=duration, step=step)
if normal.get("status") == burst.get("status") == "completed" and not any(
reason.endswith("incomplete_or_failed") for reason in result["blockers"]
):
for key, current in (("normal_trigger", normal), ("event_trigger", burst)):
result[key] = pressure_preview(pipe, case.occurred_at, duration, step,
histories[case.occurred_at], current["nodes"], design.selection_rule)
if result["normal_trigger"]["raised"]:
result["blockers"].append("normal_control_false_positive")
if not result["event_trigger"]["raised"]:
result["blockers"].append("event_rule_did_not_trigger")
coefficient = 0.65 * area / 10000 * (19.6 ** 0.5) * 1000
# PDA demand can change with pressure: demand delta alone is not emitter flow.
result["emitter_flow_m3_s"] = [coefficient * max(row["pressure"], 0) ** 0.5 / 1000
for row in burst["nodes"][pipe.emitter_node_id]]
result.update(case_id=case.case_id, severity=severity, orifice_area_cm2=area,
passed=not result["blockers"])
report["cases"].append(result)
level_passed &= result["passed"]
save_json(report_path, report)
print(f"{case.case_id}-{severity}: physical and rule checks {'PASS' if result['passed'] else 'FAIL'}", flush=True)
if level_passed:
passed_levels.append(severity)
if severity == "severe" and not level_passed and not args.all_severities:
break
case_ids = {case.case_id for case in cases}
report["selection"][pipe.pipe_id] = select_calibrated_area(
pipe, passed_levels, [case for case in report["cases"] if case["case_id"] in case_ids], args.all_severities,
)
save_json(report_path, report)
report["status"] = "completed"
save_json(report_path, report)
print(f"calibration complete; report: {report_path}", flush=True)
return 0
except Exception as exc:
frames = traceback.extract_tb(exc.__traceback__)
location = frames[-1] if frames else None
suffix = f" at {location.filename}:{location.lineno}" if location else ""
if report is not None and report_path is not None:
report.update(status="failed", failure_type=type(exc).__name__)
save_json(report_path, report)
print(f"calibration failed ({type(exc).__name__}){suffix}", file=sys.stderr)
return 1
if __name__ == "__main__":